-  Connect the blue wire of the harness to the back 

of the blower prover switch.

-  Connect the yellow wire of the harness to the 

remaining terminal on the blower prover switch.

-  Connect the green wire of the harness to the 

ground screw where the green wire with a yel-

low trace, from the blower motor, is connected.

-  Connect the black wire of the harness to the 

black wire from the blower motor.

-  Connect the white wire of the harness to the 

white wire from the blower motor.

5.  Replace the cover to the blower's junction box.

3.3   Connect the Heater to the UC1 

Controller

The installer must construct a wire harness of the 

length needed to connect the heater to the UC1 con-

troller. Use wire of 20 AWG minimum with insulation 

rated at 90

o

C or higher. Installation can be made simpler 

by matching the colors of the wires in the heater, i.e. 

black with a yellow trace, yellow, black and purple. In 

any case the connections must be per the wiring dia-

gram (see Figure 10 or 11). Run the wires in approved  

conduit.

Figure 9.  Connections at the Power Venter Blower  

 

  Junction Box

3.3.1 

Connections at the LD Heater

Three (3) copper wires of the type described above 

must be provided to connect the heater control system to 

the UC1 controller.
1.  Remove the button plug from the hole on the right 

side of the heater. The hole is located near the 

front, just above the louver vent.

2.  Connect the conduit to the side of the heater using 

a conduit connector and nut. 

3.  Strip the insulation from each of the wires that will 

lead to the UC1 controller about 1/2" from the end.

4.  Locate the yellow wire installed on the transform-

er, the purple wire installed on the "TH" terminal 

of the ignition control during the steps in Section 

3.1.1 and the black wire connected to the "F2" 

terminal on the ignition control. 

5.  Using the wire nuts provided in the kit, make the 

following connections in the heater's vestibule (see 

Figure 10, Wiring Diagram).
-  Connect the black wire from "F2" on the igni-

tion control inside the heater to wire " a " of the 

field constructed wire harness.

-  Connect the yellow wire of the heater's trans-

former to wire " b " of the field constructed wire 

harness.

-  Connect the purple wire of the heater's ignition 

control to wire " c " of the field constructed wire 

harness.

3.3.2 

 Connections at the LJ Heater

Four (4) copper wires of the type described in Sec-

tion 3.3 must be provided to connect the heater control 

system to the UC1 controller.
1.  Remove the button plug from the hole on the right 

side of the heater. The hole is located near the 

front, just above the louver vent.

2.  Connect the conduit to the side of the heater using 

a conduit connector and nut. 

3.  Strip the insulation from each of the wires that will 

lead to the UC1 controller about 1/2" from the end.

4.  Locate the purple wire installed on the water 

pressure switch, during the steps in Section 3.1.2 

and the black wire connected to the high voltage 

assembly that was cut and stripped.

5.  Using the wire nuts provided in the kit, make the 

Содержание R0412001

Страница 1: ...u with all of the major compo nents of the system that you will need to install the side wall vent Due to the different possible configurations for venting we do not supply the vent pipe elbows tees w...

Страница 2: ...nfiguration consists of an initial vertical section of vent pipe see Figure 2 Either configuration must meet the following constraints 1 The draft hood must be connected directly to the heater as per...

Страница 3: ...he heater with power 2 Remove the heater door 3 Locate the common terminal on the transformer There will be a yellow wire with a piggy back terminal attached to the transformer and a green wire with a...

Страница 4: ...mp relay over the bracket and use the screws removed earlier to secure the bracket and the pump relay to the back panel see Figure 6 Figure 3 Remove the Cover of the High Voltage Assembly Figure 4 Mou...

Страница 5: ...or bracket included in the kit must be installed to deflect the air around the igniter allowing it to heat enough to ignite the gas The air deflector bracket is not needed on the mod el LD heater beca...

Страница 6: ...he side of the heater using a conduit connector and nut 3 Strip the insulation from each of the wires that will lead to the UC1 controller about 1 2 from the end 4 Locate the yellow wire installed on...

Страница 7: ...LD LJ Side Wall Vent Kit Instructions Page 7 Figure 10 Wiring Diagram for Connecting a Model LD Heater to a Side Wall Power Venter F2 F1...

Страница 8: ...Page 8 Figure 11 Wiring Diagram for Connecting a Model LJ Heater to a Side Wall Power Venter...

Страница 9: ...ler NOTE Power connection to the controller requires a three 3 conductor copper wire harness that is run in a conduit from the power supply to the con troller These components must be supplied by the...

Страница 10: ...tch es must remain in the off down position see Figure 12 3 5 2 Jumper Placement in the UC1 Controller Installed on a Model LD Heater The Jandy LD heater uses a 24V signal to activate the power venter...

Страница 11: ...peration and enables the heater to begin its ignition se quence 3 When the igniter is hot enough the gas valve opens and burner ignition takes place 4 When the call for heat ends the burners are shut...

Страница 12: ...EDUCER 9 X 6 FOR MODEL 400 1 11 WIRE NUTS 3 3 3 12 YELLOW WIRE ASSEMBLY MODEL LD ONLY 1 1 1 13 PURPLE WIRE ASSEMBLY 1 1 1 14 1 4 DOUBLE MALE X 1 4 FEMALE CONNECTOR MODEL LD ONLY 1 1 1 15 BLOWER RELAY...

Отзывы: