Page 4
11.
Modification of Heater for High Altitude:
The Jandy Lite2 model LD heater is normally
shipped from the factory in the low altitude (sea
level) operational configuration. When requested,
the heaters can be configured and shipped for
higher altitudes. For field conversions to change
altitude configurations, manifold kits for mid
altitudes and high altitudes are available from
your Jandy pool products dealer or by contacting
the Customer Service Department at (707) 776-
8200 extension 245. See Section 11, “Parts List”,
of this manual for the correct kit number for the
manifold assembly needed for your altitude.
Table 1 defines the altitude designations as
described by the “Standard for Gas Fired Pool
Heaters”, ANSI Z21.56 in the United States and
"Gas Fired Appliances For Use At High Alti-
tudes", CAN 1-2.17 in Canada.
1.7.2 Dimensions
See Figure 1 (following page) for a diagram
showing the heater's exterior dimensions and dimen-
sions to critical connections on the heater.
SECTION 2.
Installation Instructions
WARNING
Improper installation or maintenance can cause
nausea or asphyxiation from carbon monoxide in flue
gases which could result in severe injury, or death.
For indoor installations, as an additional measure of
safety, Jandy Pool Products, Inc. strongly
recommends installation of suitable Carbon
Monoxide detectors in the vicinity of this appliance
and in any adjacent occupied spaces
AVERTISSEMENT
Une installation ou un entretien inadéquat peut
causer la nausée ou l’asphyxie en raison du
monoxyde de carbone présent dans les gaz de
combustion et même entraîner des blessures graves
ou la mort. Pour les installations intérieures, comme
mesure de sécurité additionnelle, Jandy Pool
Products, Inc. recommande fortement l’installation de
détecteurs de monoxyde de carbone près de cet
appareil ainsi que dans les espaces adjacents
occupés.
2.1 Introduction
Install the Lite2 heater, vent caps and drafthoods
in accordance with the procedures in this manual, local
codes and ordinances, and in accordance with the
latest edition of the appropriate national code (see
Section 1.4 "Codes and Standards").
All gas-fired products require correct installation
Table 1. Altitude Designations for the Lite2 Heater.
to assure safe operation. The requirements for pool
heaters include the following:
1.
Field assembly (if required)
2.
Appropriate site location (clearances) and
flooring
3.
Sufficient combustion and ventilation air
4.
Properly sized gas meter and piping
5.
Proper electrical wiring
6.
Adequate water flow
This manual provides the information needed to
meet these requirements. Review all application and
installation procedures completely before continuing
the installation.
2.2. Field Assembly
The Lite2 heater is shipped from the factory with
the top assembly in the low-profile configuration for
outdoor installation. The Lite2 heater is design certi-
fied for indoor installation (U.S. only) when equipped
with a drafthood, which must be installed without
modification.
The Lite2 heater is also certified for installation
in an outdoor shelter in Canada when equipped with a
drafthood. An outdoor shelter is an enclosure not
normally occupied which does not communicate
directly with occupied areas.
Check the rating plate on the heater or the Parts
List (Section 11) of this manual for the correct Jandy
drafthood or vent cap part number. See instructions
supplied with the drafthood or vent cap for installation
and attachment. When the drafthood is used, locate
the heater so as to be in the same atmospheric pres-
sure zone as the combustion air inlet to the heater.
ALTITUDE
UNITED
CANADA
DESIGNATION
STATES
LOW ALTITUDE
0-3000 FT
0-2000 FT
(0-610 m)
MID ALTITUDE
3001-6000 FT
2001-4500 FT
(611-1370 m)
HIGH ALTITUDE
6001-10,000 FT
NOT
APPLICABLE
LP
LOW ALTITUDE
0-5000 FT
0-4500 FT
(0-1370 m)
HIGH ALTITUDE
5001-10,000 FT
NOT
APPLICABLE
NATURAL GAS
Содержание Lite2