Page 24
Minimum
Minimum
Maximum
Size
GPM (LPM)
°F
(°C)
°F
(°C)
125
20
(76)
27
(15)
36
(20)
175
20
(76)
33
(19)
42
(24)
250
25
(95)
33
(19)
42
(24)
325
30
(114)
28
(16)
38
(21)
400
30
(114)
30
(17)
39
(22)
Table 6. Temperature Rise and Minimum Flow Rates
7.
Record the temperature indicated by the ther-
mometer (cold water).
8.
Turn the heater ON following the lighting instruc-
tions found on the inside of the heater.
9.
Allow the heater to run for about 3 minutes.
Record the new temperature reading (heated
water).
10.
Subtract the first temperature reading (cold
water) from the second temperature reading
(heated water). The difference between the two
readings is the
temperature rise
. The tempera-
ture rise should be within the range shown in
Table 6.
11.
If the temperature rise is below the minimum
range indicated, two possibilities arise:
a.
The supply gas volume is too low.
b.
The system's water flow exceeds 125 GPM
(475 LPM), and requires a manual bypass valve
for proper operation (see Figure 6).
12.
If the temperature rise is above the maximum,
there is not enough water flowing through the
heater. Check for clogging in the water filter or
restriction in the water pipes.
CAUTION
Operating the heater with the temperature rise above
maximum or below the minimum can damage the
heater and may void the warranty.
ATTENTION
Opérer le chauffe-piscine au-dessus du niveau de
température maximale ou sous le niveau de
température minimale recommandée, peut
endommager le chauffe-piscine et ainsi annuler la
garantie.
13.
If the temperature rise is within the correct
range, complete the procedure as follows:
a.
Turn heater OFF.
b.
Wait 3 minutes, turn filter pump OFF.
c.
Remove thermometer and Pete's plug.
d.
Replace the drain plug.
7.7 Adjusting the Manual Bypass Valve
If a manual bypass valve is installed, use the
following procedures to adjust the bypass valve:
1.
Clean pool filter.
2.
Remove drain plug located on the inlet/outlet
header of the heater and replace it with a Pete's
plug.
3.
Insert a pocket thermometer (see Figure 14)
through the Pete's plug into the header.
4.
Close manual bypass valve.
5.
Turn on the temperature control to the OFF
position.
6.
Repeat steps 6 through 10 of the temperature
rise test (see Section 7.6).
7.
If the temperature rise is below the minimum
stated in Table 6, open the manual bypass valve
until temp rise climbs between the min. and max.
range for your size heater. If the minimum
temperature rise stated in Table 6 cannot be
reached with the manual bypass fully open, then
the gas supply volume is too low.
8.
If the temperature rise is above the maximum,
there is not enough water flowing through the
heater. Check for clogging in the water filter or
restriction in the water pipes.
9.
Once the temperature rise is within the correct
range, safety wire the handle of the manual
bypass valve in place and tag the valve to
prevent change in the water flow.
SECTION 8.
Maintenance
8.1 Water Chemistry
The mineral content of swimming pool water
increases daily due to natural evaporation and the
addition of sanitizing chemicals. If the mineral concen-
tration in the pool gets too high, the excess minerals
will deposit on the walls of the pool, in the filter
system, and in the heater tubes.