Jandy
®
UV Medium Pressure | Installation & Operation Manual
3.4 Control Panel: Field Wiring Diagram
T. block
Control panel input
Cable
Wire description
PE
POWER 240 VAC / 50-60 Hz / 1-phase
(1)
GROUND
1
PHASE
2
NEUTRAL
PE
UV REACTOR BONDING
(2)
GROUND
3
UV LAMP OUTPUT
LP-035/1
RED
4
LP-035/2
RED
5
SW-11
LP-035/1
BLACK “1”
6
SW-12
BLACK “2”
7
SW-21
LP-035/2
BLACK “1”
8
SW-22
BLACK “2”
9
SI5004 FLOW SENSOR INPUT
EVC-005
BROWN
10
WHITE
11
BLUE
12
UVX-SE RADIATION SENSOR INPUT
EVC059
WHITE
13
BROWN
14
BLACK
15
GREY
16
TM4411
EVC-005
BROWN
17
WHITE
18
BLUE
19
FLOW SWITCH INPUT
(3)
POTENTIAL-FREE CONTACT
20
21
EXTERNAL STOP INPUT
(4)
POTENTIAL-FREE CONTACT
22
23
WIPER DRIVER (optional module) (1)
WPA-05
“1” (AC)
Wiper driver
(JUVMPAUTO)
24
“2” (SIGNAL)
25
“3” (GROUND)
(1) Not supplied with the unit
(2) Not supplied with the unit. Bonding must be made with a solid copper conductor minimum No. 8 AWG
(USA) / 6 AWG (Canada).
(3) Default bridged input
(4) Input logics