background image

Page 16

SECTION 11.
Pump Curves

11.1    Jandy™ PHP & PHPU Pump Curves

Flow Rate, GPM

PSI

Feet

Total Discharge Head

PHP.75/PHPU1.0

PHP1.0/PHPU1.5

PHP1.5/PHPU2.0/PHP1.5-2/PHPU2.0-2*

PHP2.0/PHPU2.5/PHP2.0-2/PHPU2.5-2*

PHP3.0

* High-speed only

Содержание HHPlus Series

Страница 1: ...stallation and or operation can create dangerous electrical hazards which can cause high voltages to run through the electrical system possibly causing death serious injury or property damage Improper...

Страница 2: ......

Страница 3: ...7 SECTION 6 Start up 6 1 Pump Start up 7 SECTION 7 Use and Maintenance 7 1 General Maintenance 8 7 2 Winterizing the Pump 8 SECTION 8 Troubleshooting 8 1 Troubleshooting 9 SECTION 9 Speciality Service...

Страница 4: ...e 8 Equipment that is incorrectly pressure tested may fail causing severe injury or property damage Pressure testing should only be done by trained pool spa professionals 9 Chemical spills and fumes c...

Страница 5: ...of the pool it is best to locate the pump within one 1 foot of the water level A check valve is recommended on the suction line to the pump 3 2 2 If the pump is located below water level valves shoul...

Страница 6: ...ocal codes SECTION 5 Electrical Verification Installation 5 1 Check for Correct Voltage 5 1 1 The correct voltage as specified on the pump data plate is necessary for proper performance and long motor...

Страница 7: ...tighten the lid to make an air tight seal Do not use any tools to tighten the lid hand tighten only Make sure all valves are open and the unions are tight 7 Turn on the pump 8 Once all the air has lef...

Страница 8: ...nd reinstall them when the cold weather is over Use a silicone sealant around the base of the drain plugs threads when reinstalling 6 Keep the motor covered and dry Note Covering the pump with plastic...

Страница 9: ...gently tighten with a large pair of tongue and groove pliers DO NOT over tighten 8 1 5 If there is no air in the system but the pressure is still low a It is possible that debris is caught in the pump...

Страница 10: ...bris Remove any debris found inside 4 Replace the basket and lid 5 Switch on the circuit breaker to the pump motor 6 Turn on the pump and see if the problem is solved 7 If the impeller is still blocke...

Страница 11: ...3 6 Check for debris around the pump body o ring seat as this will cause leaks Clean and place the o ring on the mounting bracket assembly 7 Slide the motor assembly into the pump body and press firm...

Страница 12: ...et assembly onto the impeller 5 Use Windex or alcohol to remove any fingerprints from the ceramic seal 6 Using a hammer tap the old metal w spring seal out of the mounting bracket from the back side 7...

Страница 13: ...ment of the mounting bracket to the motor See Fig 3 4 Replace the motor with an identical make and model 5 Replace the four 4 bolts holding the mounting bracket to the motor 6 Follow steps 1 thru 15 o...

Страница 14: ...PHP Series All R0559100 7 Mounting Foot Assy JHP PHP Series All R0556000 8 Pot Lid w collar PHP Series All R0558900 9 Pot Basket PHP Series All R0559000 10 Gasket Body JHP PHP Series All R0555900 11...

Страница 15: ...Page 15 Jandy Pumps Figure 9 PHP PHPU Exploded View 1 16 Qty 6 12 8 9 19 Qty 2 18 6 14 15 7 17 Qty 4 5 10 3 4 11 13 Qty 2 20 18 2...

Страница 16: ...N 11 Pump Curves 11 1 Jandy PHP PHPU Pump Curves Flow Rate GPM PSI Feet Total Discharge Head PHP 75 PHPU1 0 PHP1 0 PHPU1 5 PHP1 5 PHPU2 0 PHP1 5 2 PHPU2 0 2 PHP2 0 PHPU2 5 PHP2 0 2 PHPU2 5 2 PHP3 0 Hi...

Страница 17: ...5 115 230 2 56lbs 27 28 PHP2 0 2 0 230 2 63lbs 28 27 5 8 1 8 8 17 A 13 8 12 MODEL HP VOLTAGE PIPE CARTON OVERALL LENGTH A NO SIZE WEIGHT Franklin Century PHPU1 0 75 115 230 2 44lbs 26 26 PHPU1 5 1 0 1...

Страница 18: ...Page 18 Notes...

Страница 19: ......

Страница 20: ...OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY LAARSAND JANDY EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIAB...

Отзывы: