background image

Page 4 

ENGLISH

  

 

Jandy

®

 Pro Series FHPM Pump   

|

   Installation & Operation Manual

SAVE THESE INSTRUCTIONS

 

WARNING

Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to 

fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment. 

 

CAUTION

Do not start pump dry! Running the pump dry for any length of time will cause severe damage and will void the 

warranty.

 

WARNING

To minimize the risk of severe injury or death the filter and/or pump should not be subjected to the piping system 

pressurization test.

Local codes may require the pool piping system to be subjected to a pressure test. These requirements are 

generally not intended to apply to the pool equipment such as filters or pumps.

Zodiac

®

 pool equipment is pressure tested at the factory.

However, if the WARNING cannot be followed and pressure testing of the piping system must include the filter 

and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
•  Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and 

secured before testing.

•  RELEASE ALL AIR in the system before testing.
•  Water pressure for test must NOT EXCEED 35 PSI.
• 

Water temperature for test must NOT EXCEED 100°F (38°C).

•  Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.

NOTICE: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult  equipment 

manufacturer.

 

CAUTION

This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. 

Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building 

such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily 

disassembled for storage and reassembled to its original integrity.

 

CAUTION

Do not install within an outdoor enclosure or beneath the skirt of a hot tub or portable spa. The pump requires 

adequate ventilation to maintain air temperature at less than the maximum ambient temperature rating listed on 

the motor rating plate. 

Содержание FHPM10

Страница 1: ...this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death...

Страница 2: ...tion Guidelines 5 Section 2 General Description 6 2 1 Introduction 6 2 2 Description 6 Section 3 Installation 6 3 1 Plumbing 6 3 2 Electrical Installation 9 3 3 Pressure Testing 11 Section 4 Operation...

Страница 3: ...e pump without the test button being pushed a ground current is flowing indicating the possibility of electrical shock Do not use the pump Disconnect the pump and have the problem corrected by a quali...

Страница 4: ...LLOWING SAFETY INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing...

Страница 5: ...ain See Figure 1 More than one 1 pump can be connected to a single suction line as long as the requirements above are met Water Velocity The maximum water velocity through the suction outlet assembly...

Страница 6: ...e chosen for their strength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which for...

Страница 7: ...he pump needs to be protected from the rain and sun 6 Proper ventilation is required for the pump to operate normally All motors generate heat that must be removed by providing proper ventilation 7 Pr...

Страница 8: ...o and WhisperFlo are registered trademarks of Pentair Water Pool and Spa Inc Pump Height Suction Side Height No Base Required Hayward Super Pump Pentair SuperFlo Sta Rite SuperMax Small Base Hayward S...

Страница 9: ...nd it eliminates the possibility of leaks at threaded adapters 4 The FHP Pump must be connected to at least two 2 main drains suction outlets for each pool pump suction line Each drain suction outlet...

Страница 10: ...n Sec 3 2 3 and in accordance with the requirements of the National Electrical Code NEC or in Canada the Canadian Electrical Code CEC the pump motor must be bonded to all metal parts of the swimming p...

Страница 11: ...surized water in the system 4 Carefully observe the system for leaks and or pressure decay Section 4 Operation 4 1 Start up CAUTION Never run the pump without water Running the pump dry for any length...

Страница 12: ...rned to the proper position for normal operation 8 Open the pressure release valve on the filter and make sure it is clean and ready for operation 9 Turn on the power to the pump Once all the air has...

Страница 13: ...hould create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not over tighten There is no air in the system but the pressure is still low It is p...

Страница 14: ...0 2 R0479702 4 Diffuser FHP Diffuser w O ring Hardware Backplate O ring 1 5 1 5 2 2 0 2 0 2 2 5 R0479701 5 Mechanical Seal Carbon and Ceramic 1 Set All R0479400 6 Pump Body FHP Body and Backplate O r...

Страница 15: ...120 130 140 150 160 170 180 190 200 210 220 230 240 250 0 5 10 15 20 25 30 35 FloPro FHPM 1 5 HP 3450 RPM FloPro FHPM 1 0 HP 3450 RPM FloPro FHPM 75 HP 3450 RPM FloPro FHPM 2 0 HP 1725 RPM FloPro FHP...

Страница 16: ...acers Certified to NSF ANSI Standard 50 CONFORMS TO UL STD 1081 CERTIFIED TO CSA STD C22 2 NO 108 7 4 Physical and Operational Specifications 7 4 1 Specifications Table 4 FHPM Pump Specifications Mode...

Отзывы: