5.1  Routine Maintenance

 

WARNING

To avoid the risk of property damage, severe 

personal injury, and/or death, turn off the pump and 

switch off the circuit breaker to the pump motor 

before servicing the pump.

Inspect the pump basket for debris by looking through 

the clear pump lid. Remove any debris, because as 

debris accumulates, it will begin to block the flow 

of water through the pump. Keep the basket clean to 

improve the performance of the pump.

1. 

Turn off the power to the pump. If the pump is 

located below the water level, close the isolation 

valves on the suction and discharge sides of the 

pump to prevent backflow of water. 

2. 

Turn the lid’s locking ring counter-clockwise 

until ‘START’ aligns with the ports. Carefully 

remove the lid.

 

CAUTION

A misaligned basket will cause the lid to be 

improperly seated, allowing an air leak, which could 

result in pump damage.

3. 

Lift the basket out of the pump. Dispose of all 

debris and thoroughly clean the basket, making 

sure all the holes are open. Using a garden hose, 

spray the basket from the outside to help clear 

the holes. Remove any remaining debris by 

hand.

4. 

Replace the basket in the pump by aligning the 

open section of the basket with the inlet pipe. If 

aligned properly, the basket will drop easily into 

place. 

Do not force it into place.

5. 

Remove the lid o-ring and remove debris 

around the lid o-ring seat, as this will cause air 

leaks into the system. Clean the lid o-ring and 

replace it.

6. 

Replace the lid with locking ring on the pump 

housing. Align ‘START’ with the ports and 

turn the lid’s locking ring clockwise until 

‘LOCKED’ aligns with the ports. 

Hand-tighten 

the lid to make an air tight seal. 

Do not use any 

tools to tighten the lid.

7. 

Verify that all valves have been returned to the 

proper position for normal operation.

8. 

Open the pressure release valve on the filter, and 

make sure it is clean and ready for operation. 

9. 

Turn on the power to the pump. Once all the 

air has been evacuated from the filter, close the 

filter pressure release valve.

5.2  Winterizing the Pump

 

CAUTION

The pump 

must

 be protected when freezing 

temperatures are expected. Allowing the pump 

to freeze will cause severe damage and void the 

warranty.

 

CAUTION

Do not use antifreeze solutions in the pool, 

spa, or hot tub systems!

 Antifreeze is highly toxic 

and may damage the circulation system. The only 

exception to this is Propylene Glycol. For more 

information see your local pool/spa supply store or 

contact a qualified swimming pool service company.

1. Drain 

all

 water from the pump, system 

equipment, and piping.

2. 

Remove the two (2) drain plugs. Store the drain 

plugs in a safe location and reinstall them when 

the cold weather season is over. 

Do not lose the 

o-rings.

3. 

Keep the motor covered and dry. Do not cover it 

with plastic, as this will create condensation and 

this moisture will damage the pump. 

NOTE

  To protect your pump, Zodiac Pool Systems LLC 

recommends having a qualified service technician or 

electrician properly disconnect the electrical wiring 

at the switch or junction box. Once the power is 

removed, the two (2) unions can be loosened and the 

pump stored indoors. For safety, and to prevent entry 

of contaminants, reinstall all conduit and terminal box 

covers.

4. 

When the system is reopened for operation, 

make sure all piping, valves, wiring, and 

equipment are in accordance with the 

manufacturer’s recommendations. Pay close 

attention to the filter and electrical connections.

5. 

The pump must be primed prior to starting; refer 

to 

Section 4.1, Start-up

.

Section 6.  Troubleshooting

Zodiac Pool Systems LLC strongly recommends that 

you call a qualified service technician to perform any 

repairs on the pump system. To locate a qualified 

technician, check your local yellow pages or visit  

www.zodiacpoolsystems.com

 and click on “Support.”

Содержание FHPM10

Страница 1: ...this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death...

Страница 2: ...tion Guidelines 5 Section 2 General Description 6 2 1 Introduction 6 2 2 Description 6 Section 3 Installation 6 3 1 Plumbing 6 3 2 Electrical Installation 9 3 3 Pressure Testing 11 Section 4 Operation...

Страница 3: ...e pump without the test button being pushed a ground current is flowing indicating the possibility of electrical shock Do not use the pump Disconnect the pump and have the problem corrected by a quali...

Страница 4: ...LLOWING SAFETY INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing...

Страница 5: ...ain See Figure 1 More than one 1 pump can be connected to a single suction line as long as the requirements above are met Water Velocity The maximum water velocity through the suction outlet assembly...

Страница 6: ...e chosen for their strength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which for...

Страница 7: ...he pump needs to be protected from the rain and sun 6 Proper ventilation is required for the pump to operate normally All motors generate heat that must be removed by providing proper ventilation 7 Pr...

Страница 8: ...o and WhisperFlo are registered trademarks of Pentair Water Pool and Spa Inc Pump Height Suction Side Height No Base Required Hayward Super Pump Pentair SuperFlo Sta Rite SuperMax Small Base Hayward S...

Страница 9: ...nd it eliminates the possibility of leaks at threaded adapters 4 The FHP Pump must be connected to at least two 2 main drains suction outlets for each pool pump suction line Each drain suction outlet...

Страница 10: ...n Sec 3 2 3 and in accordance with the requirements of the National Electrical Code NEC or in Canada the Canadian Electrical Code CEC the pump motor must be bonded to all metal parts of the swimming p...

Страница 11: ...surized water in the system 4 Carefully observe the system for leaks and or pressure decay Section 4 Operation 4 1 Start up CAUTION Never run the pump without water Running the pump dry for any length...

Страница 12: ...rned to the proper position for normal operation 8 Open the pressure release valve on the filter and make sure it is clean and ready for operation 9 Turn on the power to the pump Once all the air has...

Страница 13: ...hould create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not over tighten There is no air in the system but the pressure is still low It is p...

Страница 14: ...0 2 R0479702 4 Diffuser FHP Diffuser w O ring Hardware Backplate O ring 1 5 1 5 2 2 0 2 0 2 2 5 R0479701 5 Mechanical Seal Carbon and Ceramic 1 Set All R0479400 6 Pump Body FHP Body and Backplate O r...

Страница 15: ...120 130 140 150 160 170 180 190 200 210 220 230 240 250 0 5 10 15 20 25 30 35 FloPro FHPM 1 5 HP 3450 RPM FloPro FHPM 1 0 HP 3450 RPM FloPro FHPM 75 HP 3450 RPM FloPro FHPM 2 0 HP 1725 RPM FloPro FHP...

Страница 16: ...acers Certified to NSF ANSI Standard 50 CONFORMS TO UL STD 1081 CERTIFIED TO CSA STD C22 2 NO 108 7 4 Physical and Operational Specifications 7 4 1 Specifications Table 4 FHPM Pump Specifications Mode...

Отзывы: