Auxiliary Load Connection Requirements
WARNING
ELECTRICAL SHOCK HAZARD
Due to the potential risk of fire, electric shock, or
injuries to persons, Zodiac
®
Pumps and any auxiliary
loads must be installed in accordance with the
National Electrical Code
®
(NEC
®
), all local electrical
and safety codes, and the occupational Safety and
Health Act (OSHA). Copies of the NEC may be
ordered from the National Protection Association, 470
Atlantic Ave., Boston, MA 02210, or from your local
government inspection agency.
In Canada, Zodiac Pumps must be installed in
accordance with the Canadian Electrical Code (CEC).
• The Auxiliary Load relay contacts are rated at
230V/11A RMS. Please ensure the requirements
of the equipment to be connected to the Auxiliary
Load
do not exceed this rating
.
F1015
F1014
TP133
TP130
TP127
/100
For
Controller
1
2
230V
Auxiliary
Load
GFCI-
Protected
230V
Power
Source 1
L2 L1
L1
(Black)
L2
(Red or
Black)
Earth
Earth
GFCI-
Protected
230V
Power
Source 2
Line
(Black)
L1
(Black)
L2
(Red or Black)
Note: Recommended Wiring Configuration
Figure 9. 230V Auxiliary Load, Separate Power
Source Wiring Diagram
F1015
F1014
TP133
TP130
TP127
/100
For
Controller
1
2
115V
Auxiliary
Load
GFCI-
Protected
230V
Power
Source
L2 L1
L1
(Black)
L2
(Red or
Black)
Earth
Earth
GFCI-
Protected
115V
Power
Source
Line
(Black)
Line
(Black)
Neutral
(White)
Figure 10. 115V Auxiliary Load, Separate Power
Sources Wiring Diagram
Auxiliary Load Operation Characteristics
Auxiliary Load relay contact activation is speed-
dependent, and behaves as follows:
Contact Closure
From a stopped condition, there is a three-minute
delay before the Auxiliary Load contact is closed when
the motor speed reaches and maintains a speed of at
least 1725 RPM.
From a running condition at below 1725 RPM, there
is a five-second delay before the Auxiliary Load contact
is closed when the motor speed reaches and maintains a
speed of at least 1725 RPM.
Contact Opening
If the pump speed is below 1725 RPM, the
Auxiliary Load contact is opened. Contact openings are
always immediate.
Page 14
Jandy
®
Pro Series ePump™ Series Pump | Installation and Operation Manual
ENGLISH