         WARNING

 -  NEVER OPERATE OR TEST THE FILTER SYSTEM AT MORE THAN 50 PSI

1.2 General Safety Instructions

1. Before repositioning valve(s) and before beginning the assembly, disassembly or adjustment of the clamp or 
any other service of the circulating system (A) turn the pump off and shut off any automatic controls to ensure the 
system is not inadvertently started during servicing (B) open the air release valve and (C) wait until all pressure is 
relieved (air will have stopped flowing from the air release valve).

2. Whenever installing the filter clamp follow Section 3.4 of this manual, "Clamp Installation".

3. Once service on the circulation system is complete follow Section 4 of this manual, "Start-up and Operation".

4. Maintain the circulation system properly. Replace worn or damaged parts immediately.

5. Be sure that the filter is properly mounted and positioned according to these installation instructions.

6. Do not pressure test above 50 PSI. Pressure testing must be done by a trained pool professional.

7. SAVE THESE INSTRUCTIONS.

THIS  FILTER  OPERATES  UNDER  HIGH  PRESSURE.  WHEN  ANY  PART  OF  THE 
CIRCULATING  SYSTEM,  i.e.,  FILTER,  PUMP,  VALVE(S),  CLAMP,  ETC.  IS  SERVICED,  AIR 
CAN  ENTER  THE  SYSTEM  AND  BECOME  PRESSURIZED  WHEN  THE  SYSTEM  IS 
RESTARTED.  PRESSURIZED  AIR  CAN  CAUSE  THE  FILTER  LID  TO  BE  BLOWN  OFF 
WHICH  CAN  RESULT  IN  DEATH,  SERIOUS  PERSONAL  INJURY  OR  PROPERTY 
DAMAGE.  TO  AVOID  THIS  POTENTIAL  HAZARD,  FOLLOW  ALL  OF  THE 
INSTRUCTIONS IN THIS MANUAL.

ATTENTION INSTALLER:

This  manual  contains  important  information  about  the  installation,  operation  and  safe 
use  of  this  product.  This  information  should  be  given  to  the  owner/operator  of  this 
equipment.

2

Содержание DEL Series Filters

Страница 1: ...and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Improper installation and or operation can create dangerous high pressure which can c...

Страница 2: ...p Installation 6 SECTION 4 Start up and Operation 4 1 Preparing Diatomaceous Earth 7 4 2 Coating the Filter Grids 7 4 3 New Pool and Seasonal Start up 8 4 4 Valve Operation 8 SECTION 5 Filter Disassem...

Страница 3: ...rt up and Operation 4 Maintain the circulation system properly Replace worn or damaged parts immediately 5 Be sure that the filter is properly mounted and positioned according to these installation in...

Страница 4: ...nce locate the filter as close as possible to the pool 2 The filter should be located on a level concrete slab so that the orientation of the valve outlets and pressure gauge are convenient and access...

Страница 5: ...remove the accessory package 3 With the carton in an upright position remove the filter tank from the carton 4 A visual inspection of all parts should be made now See parts list on pages 14 and 15 3...

Страница 6: ...lvent on inlet outlet coupling nuts 8 Keep piping tight and free of leaks Pump suction line leaks may cause air to be entrapped in filter tank or loss of prime at the pump Pump discharge line leaks ma...

Страница 7: ...p ring halves touch each other or are within 1 16 See Fig 6 but do not overtighten as the clamp can break If unable to tighten as indicated do not operate the filter and call a service technician imme...

Страница 8: ...o the word DIRTY on the bezel of the gauge This indicates an increased pressure of between 10 and 12 psi above original starting pressure WARNING NEVER start pump while standing within five 5 feet of...

Страница 9: ...me and the pressure will increase When the needle of the pressure gauge aligns with the arrow next to the word DIRTY on the bezel ring it is time to backwash the filter see Section 6 2 4 4 Valve Opera...

Страница 10: ...sive wear Replace if necessary 8 Assemble the manifold to the top of the assembly Make sure that the grids and outlet tube fit securely into the manifold and that the retaining rod extends up through...

Страница 11: ...ter Follow instructions in Section 5 1 4 Using a garden hose thoroughly flush all contaminates from the filter grid surfaces 5 See Section 5 2 for reassembly of the filter tank and filter grids 6 5 Cl...

Страница 12: ...ump impeller vanes blocked Pump operating under speed low voltage Presence of algae clogging filter Incorrect water chemistry Strainer baskets not being used and or broken Allows debris into pump Pump...

Страница 13: ...utlet Tube Elbow Assembly w O rings DEL48 15 Bulkhead Assembly w O ring Coupling Nuts w Flange and O ring set of 2 Inlet Elbow w O ring DEL6 Tank Bottom w Drain Plug Drain Plug w O ring DE Grid Suppor...

Страница 14: ...SECTION 10 Head Loss Curves 13 10 1 Jandy DEL Filter Design Head Loss Curves...

Страница 15: ...rranty given by Laars and Jandy No one is authorized to make any other warranties on Laars and Jandy behalf THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITE...

Отзывы: