background image

6000 Condor Drive, Moorpark, CA, USA 93021  •  707.776.8200  FAX 707.763.7785

480 S. Service Road West, Oakville, Ontario, Canada L6K 2H4  •  905.844.8233  FAX 905.844.2635

Litho in U.S.A. © Water Pik Technologies, Inc. 0503

 

 

 

For Technical Support call 707.776.8200, ext. 260 

 

 

 

 

EXCLUSIONS:

The liability of Laars and Jandy shall not exceed the repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the 
defective part, transportation to or from the factory, and any other materials required to make the repair.

This warranty does not cover failures or malfunctions resulting from the following:
              1.    Failure to properly install, operate or maintain the product(s) in accordance with our published Installation, Op er a tion and Maintenance  

 

                     Manuals provided with the product(s);
              2.    The workmanship of any installer of the product(s);
              3.    Not maintaining a proper chemical balance [pH level between 7.2 and 7.8, Total Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS)  
                     less than 2000];
              4.    Abuse, alteration, accident,   re,   ood, lightning, rodents, insects, negligence or acts of God;
              5.    Scaling, freezing, or other conditions causing inadequate water circulation;
              6.    Operating the product(s) at water   ow rates outside the published minimum and maximum speci  cations;
              7.    Use of non-factory authorized parts or accessories in conjunction with the product(s);
              8.    Chemical contamination of combustion air or improper use of sanitizing chemicals such as, introducing sanitizing chemicals upstream of the heater 
and                

cleaner hose or through the skimmer;

              9.    Overheating, incorrect wire runs, improper electrical supply, collateral damage caused by failure of O-Rings, DE grids, or cartridge elements, damage  
                     caused by running the pump with insuf  cient water;
              10.  The installation of a surge protection kit does not extend the warranty of the original product(s).

LIMITATION OF LIABILITY:

This is the only warranty given by Laars and Jandy. No one is authorized to make any other warranties on Laars and Jandy behalf. THIS WAR RAN TY IS IN LIEU 
OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, IN CLUD ING BUT NOT LIM IT ED TO ANY IMPLIED WAR RAN TIES OF FITNESS FOR A PARTICULAR 
PURPOSE AND MER CHANT ABIL I TY.  LAARS AND JANDY EXPRESSLY DISCLAIMS AND EX CLUDES ANY LI A BIL I TY FOR CON SE QUEN TIAL, IN CI -
DEN TAL, IN DI RECT OR PU NI TIVE DAMAGES FOR BREACH OF ANY EX PRESS OR IMPLIED WAR RAN TY. This warranty gives you speci  c legal rights, and 
you may also have other rights which vary from state to state or by province.

WARRANTY CLAIMS:

For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, model number, serial number and date of instal-
lation. The installer will notify the factory for instructions regarding the claim and for the location of the nearest Laars and Jandy des ig nat ed service center. If the 
dealer is not available, you can locate a service center in your area by visiting  

LIMITED WARRANTY

These warranties extend only to the   rst retail purchaser of Laars and Jandy products that have not been moved from their 
original installation sites. Laars and Jandy warrants all parts to be free from manufacturing defects in ma te ri al and work man -
ship as detailed below for the designated time frame, commencing from the date of in stal la tion. If any parts are found to have 
manufacturing defects, Laars and Jandy will provide re place ment of such de fec tive parts.

    1  year           2 years 

 

      3 years 

5 years            Lifetime

Cleaners:

Ray-Vac

®                                                                                             

                           X 

 

 

 

       

Others                                                           X

Control Systems:

AquaLink

®

 RS and Accessories                    X

AquaLink

®

 RS (w/Surge Protection)              X                X

($50 Deductable) 

                    X

($75 Deductable)

 

  

AquaSwitch

®

, Pool Control, Ji,                     

and Solar Control                                          X

Filters:                                            

X                          

 

 

 

 

   Tank

Heaters:

Lite2                                                                            Controls,  Firebox Panels,                                                 All Other Parts

                                                                                    Heat Exchanger, Burners
LX, Hi-E2                                                                     Controls,  Firebox Panels,                                                 All Other Parts
                                                                                    Heat Exchanger,
                                                                                    Fan Motor, Burners                                                            
Hot Shot                                                        X
Oil-Fired, XL-2, XL-3                    Oil Burner, Controls                                                                                           All Other Parts

                                                     Heat Exchanger,
                                                     Firebox 

Pumps:                                           

X            Motor (from Manufacturer)

Jandy Valve Actuator:                    

X            

Valves:

NeverLube

®

                                                                                                                                                              

 

       X

Others                                                           X

Water Features:                             

X

H0238800C

Содержание DEL Series Filters

Страница 1: ...and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Improper installation and or operation can create dangerous high pressure which can c...

Страница 2: ...p Installation 6 SECTION 4 Start up and Operation 4 1 Preparing Diatomaceous Earth 7 4 2 Coating the Filter Grids 7 4 3 New Pool and Seasonal Start up 8 4 4 Valve Operation 8 SECTION 5 Filter Disassem...

Страница 3: ...rt up and Operation 4 Maintain the circulation system properly Replace worn or damaged parts immediately 5 Be sure that the filter is properly mounted and positioned according to these installation in...

Страница 4: ...nce locate the filter as close as possible to the pool 2 The filter should be located on a level concrete slab so that the orientation of the valve outlets and pressure gauge are convenient and access...

Страница 5: ...remove the accessory package 3 With the carton in an upright position remove the filter tank from the carton 4 A visual inspection of all parts should be made now See parts list on pages 14 and 15 3...

Страница 6: ...lvent on inlet outlet coupling nuts 8 Keep piping tight and free of leaks Pump suction line leaks may cause air to be entrapped in filter tank or loss of prime at the pump Pump discharge line leaks ma...

Страница 7: ...p ring halves touch each other or are within 1 16 See Fig 6 but do not overtighten as the clamp can break If unable to tighten as indicated do not operate the filter and call a service technician imme...

Страница 8: ...o the word DIRTY on the bezel of the gauge This indicates an increased pressure of between 10 and 12 psi above original starting pressure WARNING NEVER start pump while standing within five 5 feet of...

Страница 9: ...me and the pressure will increase When the needle of the pressure gauge aligns with the arrow next to the word DIRTY on the bezel ring it is time to backwash the filter see Section 6 2 4 4 Valve Opera...

Страница 10: ...sive wear Replace if necessary 8 Assemble the manifold to the top of the assembly Make sure that the grids and outlet tube fit securely into the manifold and that the retaining rod extends up through...

Страница 11: ...ter Follow instructions in Section 5 1 4 Using a garden hose thoroughly flush all contaminates from the filter grid surfaces 5 See Section 5 2 for reassembly of the filter tank and filter grids 6 5 Cl...

Страница 12: ...ump impeller vanes blocked Pump operating under speed low voltage Presence of algae clogging filter Incorrect water chemistry Strainer baskets not being used and or broken Allows debris into pump Pump...

Страница 13: ...utlet Tube Elbow Assembly w O rings DEL48 15 Bulkhead Assembly w O ring Coupling Nuts w Flange and O ring set of 2 Inlet Elbow w O ring DEL6 Tank Bottom w Drain Plug Drain Plug w O ring DE Grid Suppor...

Страница 14: ...SECTION 10 Head Loss Curves 13 10 1 Jandy DEL Filter Design Head Loss Curves...

Страница 15: ...rranty given by Laars and Jandy No one is authorized to make any other warranties on Laars and Jandy behalf THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITE...