Aqua Logic

Aqua Logic

Aqua Logic

Aqua Logic

Aqua Logic

Automation and Chlorination

Installation Manual

for models

AQ-LOGIC-PS-4
AQ-LOGIC-PS-8

Содержание Aqua Logic AQ-LOGIC-PS-4

Страница 1: ...DLINE CONTROLS INC G www goldlinecontrols com 888 921 7665 Aqua Logic Aqua Logic Aqua Logic Aqua Logic Aqua Logic Automation and Chlorination Installation Manual for models AQ LOGIC PS 4 AQ LOGIC PS 8...

Страница 2: ...nal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipment One bondin...

Страница 3: ...less Remote Display Keypad 7 Optional Base Receiver 7 ValveActuators 7 3 Plumbing General Equipment 8 Turbo Cell 9 Flow Switch 9 4 Electrical Main Service 10 Wiring Grounding and Bonding 11 Circuit Br...

Страница 4: ...rommainpaneltoAquaLogic Wire conduitforfilterpumpandotherhighvoltageloads Wireforbonding Miscellaneous Utilityelectricaloutletandweatherproofcover formountingonsideofAquaLogic Mountinghardware screws...

Страница 5: ...red anexternalsubpanelcanbeused TheAquaLogiccontrolcircuitrequires120VACpower Autilityreceptacle notincluded canbemounted in the side of theAqua Logic box to provide 120VAC power if desired Installati...

Страница 6: ...are using the chlorinator features on theAqua Logic Control If you are NOT using the chlorinator it is recommended that you follow all of the other chemistry recommendations be sides salt Refer to th...

Страница 7: ...3 887 297 403 700 933 318 424 600 260 118 303 138 347 158 390 177 433 197 477 693 217 317 520 737 236 337 563 780 256 358 607 823 276 378 650 867 297 398 800 240 109 280 127 320 145 360 164 400 182 44...

Страница 8: ...ngth x Width x Average Depth x 1000 POUNDS and Kg OF STABILIZER CYANURIC ACID NEEDED FOR 80 PPM Gallons and Liters of Pool Spa water Current Stabilizer Level ppm 0 ppm 20 ppm 60 ppm 30 ppm 40 ppm 50 p...

Страница 9: ...nsertsensoruntilO ringcollarsitsflushonthehole 3 Position hose clamp over the sensor and gently tighten until O ring makes an adequate seal Do not overtighten 4 For maximum temperature accuracy cover...

Страница 10: ...ss remote display keypad Follow the steps below 1 Remove the display keypad baseplate from the cover by lifting up on the cover at the lower end of the keypad See diagram above 2 Screw the baseplate i...

Страница 11: ...Aqua Logic Aux output can be used to direct pool return water to a waterfall 7 Plumb solar system supply and return lines between the filter and heater Install a 3 way solar valve connected to Aqua L...

Страница 12: ...ptors providedbyinstaller Flow Switch TheflowswitchmustbeplumbedinthesamesectionofplumbingastheTurboCell Theflowswitchisa safety device that ensures that water is flowing through the cell before theAq...

Страница 13: ...ircuit Breaker Subpanel TheAqua Logic circuit breaker subpanel is rated for 100Aservice Run properly rated conductors L1 L2 N and ground from the primary house electrical panel to the main power conne...

Страница 14: ...may be required to be connected to ground fault circuit breakers check local and NEC CEC codes General Purpose Outlet If desired a duplex receptacle with weatherproof cover supplied by installer may b...

Страница 15: ...ure to follow the wiring diagram belowAND to configure the control logic according to the instructions on page 19 Lights Aground fault circuit breaker must be used to supply power for high voltage poo...

Страница 16: ...reisonapoolthathasbothagasheater forrapidheatingofthespa andaheat pump for economical heating of the pool IMPORTANT If you chose to use the Heater2 control output then you will not be able to use the...

Страница 17: ...o guidance is given use 105 C rated wire 3 Set any ON OFF switch on the heater to ON 4 Set the thermostat s on the heater to the maximum hottest setting Laars Heaters most models except LX 1 Turn powe...

Страница 18: ...erAquaLogicrequests whenAquaLogic Heater LEDisilluminated Pentair Purex MiniMax 1 Turn power off to heater 2 Removefactoryinstalledjumperfromthe ExtSwitch connector 3 Wire theAqua Logic to the Ext Swi...

Страница 19: ...mistake change the mode to POOL or SPA which then disables the remote control by theAqua Logic To prevent this Remove the heater touch pad connector P5 which will disable the touchpad STA RITE Heater...

Страница 20: ...it can connect to a maximum of 3 remote wired display keypads One remote wireddisplay keypadisincludedwiththeAquaLogic additionalwireddisplay keypadsmustbeordered separately Use four conductor cable t...

Страница 21: ...receiverintothe wireless connectoronthemainPCB intheAquaLogiccontrolunit Flow Switch Only applicable if the chlorinator function is enabled The flow switch cable plugs into theAqua Logic ControlCenter...

Страница 22: ...bled Toggle between Enabled default and Disabled Chlorinator Move to previous next configuration menu item Chlorinator If the chlorinator is enabled default then the cell and flow switch must also be...

Страница 23: ...r separate pool and spa settings Depending on the position of the pool spa suction valve the proper temperature setting will be used Heater Name The Aqua Logic allows you to assign any one of a number...

Страница 24: ...ng on the position of the pool spa suction valve the proper temperature setting will be used Solar Extend If Enabled the filter extend logic keeps the filter pump running beyond the normal turn off ti...

Страница 25: ...hts Name Pool Light Push to access Lights options Rotates between Manual On Off default Countdown Timer and Timeclock Rotates between all available names Move to previous next configuration menu item...

Страница 26: ...Aqua Logic main unit and each remote display keypad so that the Aux pushbutton can be labeled the same as the name that you have assigned At this time it is also a good idea to make sure that the rela...

Страница 27: ...Disabled Toggle between Enabled and Disabled default Valve3 Interlock Toggle between Enabled and Disabled default Valve3 Freeze Move to next menu item Move to next menu item for all functions except s...

Страница 28: ...tion menu item Toggle between 7 day default and Weekend Weekday time options This selection affects ALL of the timeclock logic in the Aqua Logic If 7 day is selected each timeclock will have one set o...

Страница 29: ...EDisilluminated godirectlytostep2 ifnot thencheckthefollowing Theheaterisenabled ConfigurationMenu HeaterConfig The heater temperature setting is at least 2 F greater than the water temperature Settin...

Страница 30: ...out of Service mode FCC Statement Compliance Statement Part 15 19 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause h...

Страница 31: ...e Aqua Trol or Aqua Logic electronics unit will be the sole determinant of the date of the initial system installation If a product is defective in workmanship or materials and is removed and returned...

Страница 32: ...F spa heater2 temp off 65 F 104 F pool heater2 temp off 65 F 104 F spa solar temp off 65 F 104 F pool solar temp off 65 F 104 F superchlorinate on off spa chlorinator setting 0 100 pool chlorinator se...