Page 7
ENGLISH
Jandy
®
Versa-Plumb
®
Cartridge Pool Filters
|
Installation & Operation Manual
Filter Base
Drill 5/32” Hole
Mounting Tab
Mounting Bracket
#12x1” Stainless Steel Pan
Head Screws (Qty 2)
Drill Two 3/32” Holes
Through Filter Base
1/4” x 2-1/4” S.S. Tapcon
®
Screw and S.S. Washer
3-1/2” Thick
(Min.)
Concrete Pad
than the maximum rating of any component,
install an ASME® approved automatic
pressure relief valve or pressure regulator in
the circulation system. Set the relief valve or
pressure regulator to lowest working pressure of
any of the components in the system.
3.
Place the filter on the concrete pad, lined up with
the inlet/outlet pipes. See Figures 5 and 5A.
4.
To reduce pressure losses, 2" (minimum) piping
is recommended for plumbing the system.
5.
For best efficiency use the fewest possible
number of fittings. This will prevent a restriction
in the water flow.
5.1 The CV model filter comes with a Jandy Pro
Sweep Elbow for this purpose. The sweep
elbow also includes a threaded port and plug
so that a ½" hose bib can be connected for
pressure testing. See Figure 7.
5.2 To install the sweep elbow use the following
instructions:
WARNING
To avoid an electrical shock hazard, which can result
in serious injury or death, ensure that all electrical
power to the system is turned off before approaching,
inspecting or troubleshooting any leaking valves
or plumbing that may have caused other electrical
devices in the surrounding area to get wet.
5.
To mount the pressure gauge/air release assembly
to the top of the filter tank (located in the
accessory bag):
a.
Place the smaller, thicker o-ring onto the
threads of the tank adapter, see Figure 4. Slide
the tank adapter through the coupling nut and
into the filter tank. Use the flats on the tank
adapter to tighten. Do not overtighten.
b.
Place the larger, thinner o-ring onto the gauge
housing. Thread the housing into the coupler
on the tank adapter.
c.
Orient the gauge/air release assembly in the
desired position. Raise and thread the locknut
onto the bottom of the gauge/air release
assembly. Hand tighten the nut only. Using a
wrench to tighten the nut may damage the nut,
gauge or air release assembly.
3.4 Filter Plumbing
1.
This filter operates under pressure. When
clamped properly and operated without air in
the water system, this filter will operate in a safe
manner.
2.
If the system can be subjected to higher pressure
Figure 4. Pressure Gauge/Air Release Assembly
Housing
O-Ring
O-Ring
Tank Adapter
Tank Adapter to Housing
Coupler
Anchor
Bracket
(Qty 4)
#12x1” Pan Head
Stainless Steel
Screw (Qty 8)
Tank Bottom
Filter Tank Anchor Bracket Installation
Anchor Bracket to Platform Installation
Figure 3. Anchor Bracket Installation
Содержание CL Versa-Plumb
Страница 2: ......
Страница 18: ...Page 18 FRAN AIS Jandy Filtres cartouche pour piscine Manuel d installation et d utilisation...