background image

Page 5 

ENGLISH

  

 

Jandy

®

 Versa-Plumb

®

 Cartridge Pool Filters   

|

   Installation & Operation Manual

28  in.

18

"A"

10 ½ in.

½ in.

Section 2.  General Information

2.1 Introduction

This manual contains information for the proper instal-

lation and operation of the CL and CV Jandy Cartridge 

Filters. Procedures in this manual must be followed 

exactly. For technical assistance, contact our Technical 

Support Department at 1.800.822.7933.

2.2 Description

Cartridge filters do not require sand or diatomaceous 

earth as the filter medium. Instead, the filter contains 

filter elements which are easily removed for cleaning or 

replacement.
Dirty water flows into the filter tank through the water 

line connected to the lower bulkhead (inlet) on the 

bottom half of the tank body. It is directed through the 

filter cartridge inside of the filter. The debris is collected 

in the filter and the clean water flows out of the filter 

through the upper bulkhead (outlet) on the bottom half of 

the tank body. Clean water is returned through the piping 

system to the pool.
As debris collects in the filter, the pressure will rise 

and water flow to the pool will diminish. The filter will 

eventually become so plugged with debris that it will be 

necessary to remove the filter cartridges and clean them 

with soap and water. 

NOTE

  A filter removes dirt and other suspended particles but 

does not sanitize the pool. Pool water must be sanitized 

and chemically balanced for clear water. The filtration 

system should be designed to meet local health codes. At 

a minimum, the system should turnover the total volume 

of water in your pool two to four times in a 24 hour period.

2.3  General Requirements

1. 

For best overall performance place the system as 

close to the pool as possible.

2. 

The filter should be located on a level concrete 

slab so that the orientation of the valve outlets and 

the pressure gauge are convenient and accessible 

for the installation and operation of the unit.

3. 

Protect the filter from the weather.

4. 

If fitting a chlorinator and/or any other device 

into the filtration plumbing circuit, great care 

must be exercised to ensure that the appliance is 

installed in accordance with the Manufacturer’s 

Instructions and any standards that may exist.

5. 

We recommend the use of barrel unions to connect 

each component of the water conditioning system 

to ease in future servicing. Barrel unions are 

provided with all Jandy filters.

Figure 1.  Dimensions, Jandy Pro CL and CV Series 

Cartridge Filters 

 WARNING

The maximum operating pressure for this filter is 50 

psi. Never subject the filter to operating pressure 

exceeding 50 psi. Operating pressures above 50 psi 

can cause product failure or also cause the lid to be 

blown off, which can result in death, serious personal 

injury, or property damage.

6. 

When performing hydrostatic pressure tests or 

when testing for external leaks of the completed 

filtration and plumbing system, ensure that 

the maximum pressure the filtration system is 

subjected to 

does not exceed the maximum 

working pressure of any of the components 

within the system.

 

2.4  Specifications and Dimensions

See Table 1 and Figure 1.

Table 1. 

Cartridge Filter Specifications

CL/CV

340

460

580

Filter Area (ft

2

)

340

460

580

Max. Flow (gpm)

127

150

150

Six Hour 

Capacity (gal.)

45,720

54,000

54,000

Max. Working 

Pressure (psi)

 50

 50

 50

Normal Start Up 

Pressure (psi)

6-15

6-15

6-15

Dimension "A"

41 in.

41 in.

47 in.

CL INLET

OUTLET

CV INLET

Port on 

CV Model  

Only

Port on 

CL Model  

Only

Содержание CL Versa-Plumb

Страница 1: ...product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Impr...

Страница 2: ......

Страница 3: ...ecifications and Dimensions 5 Section 3 Installation Instructions 6 3 1 Filter Location 6 3 2 Anchor Bracket Installation 6 3 3 Filter Preparation 6 3 4 Filter Plumbing 7 3 5 Clamp Installation 10 Sec...

Страница 4: ...FETY INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pres...

Страница 5: ...2 3 General Requirements 1 For best overall performance place the system as close to the pool as possible 2 The filter should be located on a level concrete slab so that the orientation of the valve...

Страница 6: ...5 ft without affecting the pump efficiency A check valve is recommended on the suction line to the pump 8 If the filter is to be installed below the water level of the pool isolation valves should be...

Страница 7: ...ctrical power to the system is turned off before approaching inspecting or troubleshooting any leaking valves or plumbing that may have caused other electrical devices in the surrounding area to get w...

Страница 8: ...n Pump Check Valve From Outlet Port To Inlet Port Filter Figure 5A CV Cartridge Filter Plumbing for Pool Spa Combination Heater Waterfall Pool Return Spa Make Up Spa Return From Pool Skimmer From Pool...

Страница 9: ...let union coupling nuts 7 Keep piping tight and free of leaks Pump suction line leaks may cause air to be entrapped in filter tank or loss of prime at the pump Pump discharge line leaks may show up as...

Страница 10: ...Nut and Threaded Rod Tightening Nut w Shoulder WARNING Follow these instructions carefully Improper clamp installation can cause product failure or also cause the filter lid to be blown off which can...

Страница 11: ...Switch off the circuit breaker to the pump motor 2 IMPORTANT Completely open air release valve on top of the filter tank to release all pressure from inside the tank and system 3 If the equipment is i...

Страница 12: ...tion system check the pressure gauge air release assembly for air or water leaks at least once a week 2 Keep the pressure gauge in good working order If you suspect a problem with the gauge Zodiac rec...

Страница 13: ...ce filter cartridges per instructions Fill pool so level is above pump inlet line Fill pump with water at basket and replace lid Technician required Replace baskets Technician or electrician required...

Страница 14: ...ed 340 R0554500 11 Tank Clamp Ring w Rod Assembly All R0357400 12 Threaded Rod and Retainer and Nut All R0357500 13 Tank O ring All R0357800 14 Outlet Tube Elbow Assembly w O rings All R0555100 15 Inl...

Страница 15: ...ridge Pool Filters Installation Operation Manual 6 6 6 6 8 9 8 9 22 11 16 22 18 11 16 11 21 11 22 20 22 14 26 19 22 15 22 23 25 18 21 14 15 26 21 23 25 21 20 15 21 19 21 21 9 2 Jandy Pro CL and CV Fil...

Страница 16: ...LLC ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the property of their respective owners H0291800 Rev H Section 10 Head Loss...

Страница 17: ...s les consignes de mise en garde et les instructions incluses avec ce produit et respectez les Le non respect des avertissements et des instructions pourrait causer des dommages mat riels des blessure...

Страница 18: ...Page 18 FRAN AIS Jandy Filtres cartouche pour piscine Manuel d installation et d utilisation...

Страница 19: ...Exigences g n rales 21 2 4 Sp cifications et dimensions 21 Section 3 Guide d installation 22 3 1 Emplacement du filtre 22 3 2 Installation des supports d ancrage 22 3 3 Pr paration du filtre 22 3 4 P...

Страница 20: ...SUIVANTES SONT RESPECT ES V rifier que tous les serre joints les boulons les couvercles les anneaux de blocage et les accessoires du syst me sont correctement install s et fix s solidement avant d eff...

Страница 21: ...r le syst me le plus pr s possible de la piscine 2 Le filtre doit tre situ sur une dalle plate en b ton afin que l orientation de la sortie des soupapes et du manom tre soit pratique et accessible pou...

Страница 22: ...re doit tre situ au dessus du niveau de l eau de la piscine il peut tre sur lev de 0 76 m 2 5 pi sans affecter l efficacit de la pompe Un clapet antiretour est recommand dans la conduite d aspiration...

Страница 23: ...coude lanc Jandy pr vu cet effet Le coude lanc comprend galement un orifice filet et un bouchon de mani re ce qu un boyau d arrosage de po puisse tre raccord pour les tests de pression Voir la Figure...

Страница 24: ...Vers l orifice d admission Filtre Figure 5A Plomberie de filtre cartouche CV pour syst mes mixtes piscine spa Chauffe piscine Chute d eau Retour la piscine Assemblage du spa Retour au spa partir de l...

Страница 25: ...as utiliser du ruban en T flon ou de la p te joint sur les raccords unions Poser les raccords unions secs et serrer la main Voir la Figure 6 AVERTISSEMENT Suivre toutes les directives des fabricants d...

Страница 26: ...etien 5 Apr s la premi re semaine de fonctionnement v rifier le serre joint et resserrer s il y a lieu 6 V rifier le serre joint du filtre au moins une fois par mois AVERTISSEMENT Suivre attentivement...

Страница 27: ...ler de d monter ou d ajuster le filtre quand il y a de l air sous pression dans le syst me Le d marrage de la pompe pendant qu il y a de l air sous pression dans le syst me peut provoquer le mauvais f...

Страница 28: ...de s curit de remplacement doit tre effectu e en conformit avec la proc dure recommand e par le fabricant des criteaux et des tiquettes 6 2 Manom tre ATTENTION Maintenir le manom tre en bon tat de fon...

Страница 29: ...a piscine de mani re ce que le niveau soit au dessus de la conduite d admission de la pompe Remplir la pompe pour qu il y ait de l eau dans le panier puis replacer le couvercle Technicien n cessaire R...

Страница 30: ...R0554500 11 Ensemble anneau de serre joint du r servoir avec tige Tous R0357400 12 Tige filet e et crou de serrage Tous R0357500 13 Joint torique du r servoir Tous R0357800 14 Ensemble tuyau de sorti...

Страница 31: ...S All Button Control Systems Operation Manual 6 6 6 6 8 9 8 9 22 11 16 22 18 11 16 11 21 11 22 20 22 14 26 19 22 15 22 23 25 18 21 14 15 26 21 23 25 21 20 15 21 19 21 21 9 2 Vue clat e des filtres CL...

Страница 32: ...L7M 1A6 1 888 647 4004 www ZodiacPoolsyStems ca Zodiac Pool Systems LLC 2882 Whiptail Loop East 100 Carlsbad CA 92010 1 800 822 7933 www ZodiacPoolSystems com Section 10 Courbes de perte de charge 10...

Отзывы: