background image

Page 4 

ENGLISH

  

 

Jandy

®

 Versa-Plumb

®

 Cartridge Pool Filters   

|

   Installation & Operation Manual

 

WARNING

•  Do not connect system to an unregulated city water system or other external source of 

pressurized water producing pressures greater than 35 PSI.

•  Pressurized air in system can cause product failure or also cause the filter lid to be blown off 

which can result in death, serious personal injury, or property damage. Be sure all air is out 

of system before operating or testing the equipment.

 

WARNING

MAXIMUM OPERATING PRESSURE OF THE FILTER IS 50 PSI. NEVER SUBJECT THE 

FILTER TO ANY OPERATING PRESSURE EXCEEDING 50 PSI.

This filter operates under high pressure. When any part of the circulating system, i.e., filter, 

pump, valve(s), clamp, etc. is serviced, air can enter the system and become pressurized when 

the system is restarted. Pressurized air can cause product failure or also cause the filter lid to 

be blown off which can result in death, serious personal injury or property damage. To avoid this 

potential hazard, follow all of the instructions in this manual.

 

WARNING

To minimize risk of severe injury or death the filter and/or pump should not be subjected to the 

piping system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These 

requirements are generally not intended to apply to the pool equipment such as filters or pumps.
Jandy Pro Series pool equipment is pressure tested at the factory.
If however this WARNING cannot be followed and pressure testing of the piping system must include 

the filter and/or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:

•  Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed 

and secured before testing.

•  RELEASE ALL AIR

 in the system before testing.

•  Water pressure for test must NOT EXCEED 35 PSI.
•  Water temperature for test must NOT EXCEED 100°F (38°C).
•  Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.  

Notice

: These parameters apply to Jandy Pro Series equipment only. For non-Jandy equipment, consult equipment manufacturer.

Section 1.  Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS

1.1  Important Safety Warning

1.2  General Safety Instructions

ATTENTION INSTALLER

This manual contains important information about the installation, operation and safe use of this 

product. This information should be given to the owner/operator of this equipment.

1. 

Use equipment only in a pool or spa installation.

2. 

Before repositioning valve(s) and before beginning the assembly, disassembly, or adjustment of the clamp, 

or any other service of the circulating system; (A) 

turn the pump off

 and shut off any automatic controls to 

ensure the system is not inadvertently started during servicing; (B) open the air release valve; (C) wait until 

all pressure is relieved (air will have stopped flowing from the air release valve).

3. 

Whenever installing the filter clamp 

follow Section 3.5

 of this manual, 

"Clamp Installation".

4. 

Once service on the circulation system is complete, 

follow Section 4

 of this manual, 

"Start-up and Operation".

5. 

Maintain circulation system properly. Replace worn or damaged parts immediately.

6. 

Be sure that the filter is properly mounted and positioned according to these installation instructions.

7. 

Do not pressure test above 35 PSI. Pressure testing must be done by a trained pool professional. 

SAVE THESE INSTRUCTIONS

Содержание CL Versa-Plumb

Страница 1: ...product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Impr...

Страница 2: ......

Страница 3: ...ecifications and Dimensions 5 Section 3 Installation Instructions 6 3 1 Filter Location 6 3 2 Anchor Bracket Installation 6 3 3 Filter Preparation 6 3 4 Filter Plumbing 7 3 5 Clamp Installation 10 Sec...

Страница 4: ...FETY INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pres...

Страница 5: ...2 3 General Requirements 1 For best overall performance place the system as close to the pool as possible 2 The filter should be located on a level concrete slab so that the orientation of the valve...

Страница 6: ...5 ft without affecting the pump efficiency A check valve is recommended on the suction line to the pump 8 If the filter is to be installed below the water level of the pool isolation valves should be...

Страница 7: ...ctrical power to the system is turned off before approaching inspecting or troubleshooting any leaking valves or plumbing that may have caused other electrical devices in the surrounding area to get w...

Страница 8: ...n Pump Check Valve From Outlet Port To Inlet Port Filter Figure 5A CV Cartridge Filter Plumbing for Pool Spa Combination Heater Waterfall Pool Return Spa Make Up Spa Return From Pool Skimmer From Pool...

Страница 9: ...let union coupling nuts 7 Keep piping tight and free of leaks Pump suction line leaks may cause air to be entrapped in filter tank or loss of prime at the pump Pump discharge line leaks may show up as...

Страница 10: ...Nut and Threaded Rod Tightening Nut w Shoulder WARNING Follow these instructions carefully Improper clamp installation can cause product failure or also cause the filter lid to be blown off which can...

Страница 11: ...Switch off the circuit breaker to the pump motor 2 IMPORTANT Completely open air release valve on top of the filter tank to release all pressure from inside the tank and system 3 If the equipment is i...

Страница 12: ...tion system check the pressure gauge air release assembly for air or water leaks at least once a week 2 Keep the pressure gauge in good working order If you suspect a problem with the gauge Zodiac rec...

Страница 13: ...ce filter cartridges per instructions Fill pool so level is above pump inlet line Fill pump with water at basket and replace lid Technician required Replace baskets Technician or electrician required...

Страница 14: ...ed 340 R0554500 11 Tank Clamp Ring w Rod Assembly All R0357400 12 Threaded Rod and Retainer and Nut All R0357500 13 Tank O ring All R0357800 14 Outlet Tube Elbow Assembly w O rings All R0555100 15 Inl...

Страница 15: ...ridge Pool Filters Installation Operation Manual 6 6 6 6 8 9 8 9 22 11 16 22 18 11 16 11 21 11 22 20 22 14 26 19 22 15 22 23 25 18 21 14 15 26 21 23 25 21 20 15 21 19 21 21 9 2 Jandy Pro CL and CV Fil...

Страница 16: ...LLC ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the property of their respective owners H0291800 Rev H Section 10 Head Loss...

Страница 17: ...s les consignes de mise en garde et les instructions incluses avec ce produit et respectez les Le non respect des avertissements et des instructions pourrait causer des dommages mat riels des blessure...

Страница 18: ...Page 18 FRAN AIS Jandy Filtres cartouche pour piscine Manuel d installation et d utilisation...

Страница 19: ...Exigences g n rales 21 2 4 Sp cifications et dimensions 21 Section 3 Guide d installation 22 3 1 Emplacement du filtre 22 3 2 Installation des supports d ancrage 22 3 3 Pr paration du filtre 22 3 4 P...

Страница 20: ...SUIVANTES SONT RESPECT ES V rifier que tous les serre joints les boulons les couvercles les anneaux de blocage et les accessoires du syst me sont correctement install s et fix s solidement avant d eff...

Страница 21: ...r le syst me le plus pr s possible de la piscine 2 Le filtre doit tre situ sur une dalle plate en b ton afin que l orientation de la sortie des soupapes et du manom tre soit pratique et accessible pou...

Страница 22: ...re doit tre situ au dessus du niveau de l eau de la piscine il peut tre sur lev de 0 76 m 2 5 pi sans affecter l efficacit de la pompe Un clapet antiretour est recommand dans la conduite d aspiration...

Страница 23: ...coude lanc Jandy pr vu cet effet Le coude lanc comprend galement un orifice filet et un bouchon de mani re ce qu un boyau d arrosage de po puisse tre raccord pour les tests de pression Voir la Figure...

Страница 24: ...Vers l orifice d admission Filtre Figure 5A Plomberie de filtre cartouche CV pour syst mes mixtes piscine spa Chauffe piscine Chute d eau Retour la piscine Assemblage du spa Retour au spa partir de l...

Страница 25: ...as utiliser du ruban en T flon ou de la p te joint sur les raccords unions Poser les raccords unions secs et serrer la main Voir la Figure 6 AVERTISSEMENT Suivre toutes les directives des fabricants d...

Страница 26: ...etien 5 Apr s la premi re semaine de fonctionnement v rifier le serre joint et resserrer s il y a lieu 6 V rifier le serre joint du filtre au moins une fois par mois AVERTISSEMENT Suivre attentivement...

Страница 27: ...ler de d monter ou d ajuster le filtre quand il y a de l air sous pression dans le syst me Le d marrage de la pompe pendant qu il y a de l air sous pression dans le syst me peut provoquer le mauvais f...

Страница 28: ...de s curit de remplacement doit tre effectu e en conformit avec la proc dure recommand e par le fabricant des criteaux et des tiquettes 6 2 Manom tre ATTENTION Maintenir le manom tre en bon tat de fon...

Страница 29: ...a piscine de mani re ce que le niveau soit au dessus de la conduite d admission de la pompe Remplir la pompe pour qu il y ait de l eau dans le panier puis replacer le couvercle Technicien n cessaire R...

Страница 30: ...R0554500 11 Ensemble anneau de serre joint du r servoir avec tige Tous R0357400 12 Tige filet e et crou de serrage Tous R0357500 13 Joint torique du r servoir Tous R0357800 14 Ensemble tuyau de sorti...

Страница 31: ...S All Button Control Systems Operation Manual 6 6 6 6 8 9 8 9 22 11 16 22 18 11 16 11 21 11 22 20 22 14 26 19 22 15 22 23 25 18 21 14 15 26 21 23 25 21 20 15 21 19 21 21 9 2 Vue clat e des filtres CL...

Страница 32: ...L7M 1A6 1 888 647 4004 www ZodiacPoolsyStems ca Zodiac Pool Systems LLC 2882 Whiptail Loop East 100 Carlsbad CA 92010 1 800 822 7933 www ZodiacPoolSystems com Section 10 Courbes de perte de charge 10...

Отзывы: