Page 9
Pool
Return
Spa
Return
Cell
Sensors
Heater
AquaPure /
ClorMatic
AquaLink RS Control
System
or Time Clock
JANDY
Figure 5.
Alternate Plumbing Confi guration with Cell and Sensors, Without Spa Bypass for Spillover, Top
View
Spa
Bypass for
Spillover
Pool
Return
Cell
Sensors
Heater
Spa
Return
AquaPure /
ClorMatic
AquaLink RS Control
System
or Time Clock
JANDY
Figure 6.
Alternate Plumbing Confi guration with Cell and Sensors, With Spa Bypass for Spillover, Top
View
3.2.2
Alternate
Plumbing
Con
fi
gurations
There are alternate plumbing layouts to allow for chlorination of the pool during spa spillover operation,
but prevent over-chlorination of the spa during “
spa only
” operation (see
fi
gures 5 and 6). The con
fi
guration
shown in Figure 5 will only chlorinate the pool. Whereas Figure 6 allows chlorination of the pool or spa. If
the AquaPure is controlled by an AquaLink RS, the AquaPure is noti
fi
ed when the AquaLink RS is in Spa
Mode and adjusts to 10% of the AquaLink RS output setting to ensure the spa is not over-chlorinated.
Note
The AquaPure is powered from the LOAD SIDE of the pool circulation pump relay or the time clock. This
ensures that the Cell only operates when the pool pump is ON. The Flow Sensor serves as a protection
device to ensure there is suffi cient fl ow for the Cell to operate.