Problem
Possible Cause
Corrective Action
“Cell On” indicator does not come on.
Chlorine Production set to 00%.
Adjust CHLORINE PRODUCTION to desired
Percentage.
If No Flow also….
Insuf
fi
cient water
fl
ow. Cell is plugged with debris,
pump has lost prime.
Remove obstruction and/or clean cell. See Page
27. Prime pump if necessary.
If No Flow also….
Flow/Temp/Salinity Sensor not plugged in.
Plug in Flow/Temp/Salinity Sensor. See page 6
Figure 2.
Salt level below 2.0 gpl.
Add salt as described on pages 18 through 20.
Problem
Possible Cause
Corrective Action
“No Flow” indicator stays on
continuously.
Pump fails to provide suf
fi
cient water
fl
ow.
Check for correct operation of the pump, i.e., loss of
pump prime or clogged strainer baskets.
Closed valves.
Check and correct all valve alignments.
Dirty
fi
lter.
Follow
fi
lter cleaning procedures.
Obstruction in the AquaPure cell.
Remove cell for inspection. Follow cleaning
procedures. See page 27.
Flow/Temp/Salinity Sensor not installed properly.
Ensure that the Flow/Temp/Salinity Sensor is
installed according to page 13 Figure 11. If not,
contact a pool professional.
Flow/Temp/Salinity Sensor not plugged in.
Plug Flow/Temp/Salinity Sensor into connector on
control center printed circuit board. Turn power to
unit off and back on (Cycle Power). See page 6
Figure 2. See also page 28, Section 6.5 step 4.
Flow/Temp/Salinity Sensor elements covered with PVC
glue, taped over, or covered with other debris.
Remove and clean Flow/Temp/Salinity Sensor.
Wrap Flow /Salinity sensor threads with te
fl
on tape
and reinstall.
See pages 12 through 14, 27 and 28.
Defective Flow/Temp/Salinity Sensor.
Contact your authorized service representative.
Problem
Possible Cause
Corrective Action
Salt level too high.
Too much salt has been added to pool.
Backwash or partially drain pool and dilute with
fresh water until salinity returns to
3.0 gpl to 3.5 gpl.