background image

Page 25

If you use a Pool Pump Timer

  The  National Spa and Pool Institute (NSPI) recommends that all water in 

a residential pool pass through the 

fi

 ltration system at least once every 12 hours (referred to as pool water 

turnover).  However, many factors have an effect on actual pump and 

fi

 lter system run times.  Pool size, 

source of water, direct sun light, indoor/outdoor, screened/unscreened, 

fi

 ltration system, cold or hot weather, 

swimmer load, rain, organic debris, algae, etc., are all factors which contribute to either more or less pool 
pump and 

fi

 lter system run times.  Because of these differences, it is extremely dif

fi

 cult to set an initial run 

time (starting point) for the pool pump and chlorinating system.

Try initially setting the Pool Pump Timer to 12 hours.  It will take a few days to get just the right pool 
pump operating time.  Adjust accordingly using the steps listed below ( Section 5.4.2, steps 1-5 ).  When 
the AquaPure is wired with a Pool Pump Timer (See page 6 Figure 2) 

results will vary greatly from one 

pool installation to the next, so this should be discussed with either the pool builder or the local pool 
professional.  The key points are:

•  Operate pool pump at least the minimum time needed for good 

fi

 ltration.

•  The Pool Pump Timer reduces energy consumption.

NOTE

   Exception - For Cold Weather Operation:  If the AquaPure is run 24 hours a day through the winter, extremely 

cold water temperatures can effect Cell life.  Sometimes it will be necessary to run the AquaPure at a very low 
production rate of 10% to 20% or to turn the unit off.  See winterizing on page 29.

5.4 Startup

 5.4.1 

Shocking

Shocking (Super Chlorination) is recommended before pool startup. 

Start out with good pool water 

from the beginning.  The AquaPure will build up a suf

fi

 cient level of chlorine for sanitation in several hours.  

However, if pool water has a high demand from the startup the AquaPure will not be able to produce enough 
chlorine to reach break point chlorination.  So, it is best to super chlorinate from an outside source at the 
time of pool startup.  Then, wait until the chlorine level has returned to 1 to 3 PPM before turning on the 
AquaPure.

 5.4.2 

Apply 

Power

1.     Turn on the pool pump switch or Pool Pump Timer.  When the AquaPure is 

fi

 rst turned on (cold), 

the unit will beep. Next it will self-calibrate the Flow/Temp/Salinity Sensor. After going through an 
internal test and calibration, the LCD will display the current setting for Chlorine Production (00% to 
100%).  During the calibration period “Wait” will appear.  “Wait” means the unit is self calibrating and 
doing internal testing.  This usually takes less than 6 minutes.

2.     Check salinity level by pressing the 

Salinity

 button.  It should read between 3.0 gpl and 3.5 gpl.  If it 

does not then press the 

Salinity

 button two or three more times until the salinity reading stabilizes.  

NOTE

   If still less than 3.0 gpl refer to pages 18 through 20 and adjust salt level.  (Maintain the Recommended 

Salinity Level of 3.0 to 3.5 gpl).  If salinity is below 2.0 gpl the AquaPure will automatically turn the cell off 
until the salinity is raised above 2.0 gpl, since operating with low salt will damage Cell.  Likewise, if salinity is 
above the range of measurement the AquaPure will automatically turn the cell off until the salinity is lowered 
to a measurable level, since operating with high salt will damage the control center.  If salinity is greater than 
3.5 gpl, see Troubleshooting, page 30.

3.     Adjust the Chlorine Production to 50% by pressing the arrow button 

B

.

Содержание AquaPure Pure700

Страница 1: ...and Operation Manual WARNING FOR YOUR SAFETY This product must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure t...

Страница 2: ......

Страница 3: ...4 Chemistry You Need to Know 17 4 5 Optimum Pool Water Conditions 18 4 6 Chlorine Testing 18 4 7 Salt NaCl sodium chloride 18 4 7 1 What Type of Salt 18 4 7 2 How Much Salt 18 4 7 3 How to Add Salt 19...

Страница 4: ...nterrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Powe...

Страница 5: ...e Production Level on the control center or by varying the number of hours the AquaPure is on each day The AquaPure automatically cleans the Cell electrodes once every 3 hours This does not interrupt...

Страница 6: ...quaLink RS485 Connector External Control ORP External Control Connector AquaLink RS485 Connector CAUTION Factory wired for 230 VAC service If available electrical service is 115 VAC the power supply w...

Страница 7: ...r heater solar etc The Cell and Sensor Tee fitting are designed to be plumbed into 2 PVC pipe Adapters can be used for systems with 1 5 plumbing Figures 3 and 4 on page 8 illustrate the recommended pl...

Страница 8: ...eater JANDY Figure 3 Recommended Plumbing Configuration with Cell and Sensors 1 Top View Spa Return Sensors Pool Return AquaPure Heater Ground Cell Mounted Vertically Figure 4 Recommended Plumbing Con...

Страница 9: ...for chlorination of the pool during spa spillover operation but prevent over chlorination of the spa during spa only operation see figures 5 and 6 The configuration shown in Figure 5 will only chlori...

Страница 10: ...the cell to operate without water flow through the cell which can create a HAZARDOUS condition Spa Return Sensors AquaPure Heater Pool Return Cell Mounted Vertically Figure 7 Hazardous Plumbing Confi...

Страница 11: ...nt the control center at eye level Leave sufficient clearance on all sides of the chassis backplate If possible leave a minimum of 9 inch 241 mm on the left side Position the backplate on the mounting...

Страница 12: ...nded for connecting the control center to a Permanent Earth Ground connection that is acceptable to the local inspection authority Refer to your local codes for the acceptable grounding wire gauge Att...

Страница 13: ...a 1 inch Pipe the Cutout is 17 7 8 inch For a 2 inch Pipe the Cutout is 19 3 8 inch ABS Union ABS Union Figure 11 Flow Temp Salinity Sensor Temperature Sensors Salinity Studs Temperature Sensors Flow...

Страница 14: ...terminals protruding from the Cell top Plug in in either direction 11 Connect the DC cord to the Control Center Feed the DC cord through the same strain relief fitting as the Flow Temp Salinity Senso...

Страница 15: ...e Jandy AquaLink RS and AquaPure use a four 4 wire connection to communicate and can be wired up to 500 feet apart Any outdoor rated four 4 conductor cable can be used Locate the appropriate screw ter...

Страница 16: ...minal bar Section 4 Pool Water Preparation 4 1 Determining Pool Size m3 of Water in Your Pool Rectangular Pools Average length meters x average width meters x average depth meters m3 capacity Circular...

Страница 17: ...p of the pool 5 Super Chlorination Shocking burns out the organic material that has combined with chlorine This frees the chlorine for sanitizing This is accomplished by raising the chlorine level qui...

Страница 18: ...surface and well away from the pool return line 4 7 Salt NaCl sodium chloride 4 7 1 What Type of Salt to Use The purer the salt the better the life and performance of the electrolytic cell Use a salt...

Страница 19: ...the pool see Troubleshooting page 30 NOTE To convert gpl grams per liter of a salt solution to PPM Parts Per Million of a salt solution multiply by 1000 i e 3 0 gpl salt X 1000 3000 PPM salt 4 7 3 Ho...

Страница 20: ...lbs 102 kg 225 lbs 113 kg 250 lbs 125 kg 275 lbs 136 kg 300 lbs 147 kg 325 lbs 159 kg 350 lbs 170 kg 375 lbs 1 75 gpl 48 kg 105 lbs 59 kg 130 lbs 68 kg 150 lbs 77 kg 170 lbs 86 kg 190 lbs 95 kg 210 l...

Страница 21: ...kg 7 50 lbs 3 7 kg 8 25 lbs 4 kg 9 00 lbs 4 4 kg 9 75 lbs 4 8 kg 10 5 lbs 5 3 kg 11 75 lbs 40 PPM 1 3 kg 2 90 lbs 1 6 kg 3 50 lbs 1 8 kg 4 00 lbs 2 kg 4 60 lbs 2 4 kg 5 25 lbs 2 6 kg 5 80 lbs 2 9 kg 6...

Страница 22: ...uttons can not be used when the AquaPure is controlled by the AquaLink RS If arrow button A or arrow button B is pressed JA in the AquaPure display indicates that the AquaLink RS is controlling the Aq...

Страница 23: ...rine Salinity Salinity is displayed along with the gpl grams per liter indicator when the Salinity button is depressed If a reading of HH appears the salinity is above 4 5 to 6 5 gpl depending on pool...

Страница 24: ...system Any changes made to the beeper volume will NOT be saved if this occurs The Boost cycle is normally activated after 10 seconds however if the key is held down until after the third beep at 15 se...

Страница 25: ...efore pool startup Start out with good pool water from the beginning The AquaPure will build up a sufficient level of chlorine for sanitation in several hours However if pool water has a high demand f...

Страница 26: ...keep your manual in a safe place Increase Chlorine Production before party time and return to normal afterwards Increase Chlorine Production when temperature goes up Increase Chlorine Production when...

Страница 27: ...ange of 3 0 3 5 gpl for optimum performance of the AquaPure If additional salt is required follow the procedures and charts described on pages 18 through 21 If salt level does not rise after 24 hours...

Страница 28: ...EANING PROCESS go on to next step d Otherwise allow the cell to remain in the solution until the foaming has stopped However do not leave in acid for more than 1 2 hour Excessive Acid Washing will dam...

Страница 29: ...it Disconnect the Flow Temp Salinity Sensor from the control center then remove it from the threaded PVC Tee Wrap Flow Temp Salinity Sensor in a plastic bag or protective covering and coil Flow Temp S...

Страница 30: ...mode and allow to run for 24 hours Recheck If still too low Super Chlorinate with outside source Take pool water sample to Pool Professional See pages 22 and 25 Low Less than 2 5 gpl salt level in po...

Страница 31: ...struction in the AquaPure cell Remove cell for inspection Follow cleaning procedures See page 27 Flow Temp Salinity Sensor not installed properly Ensure that the Flow Temp Salinity Sensor is installed...

Страница 32: ...circuit board Cycle Power Water temperature too low Winterize your pool See page 29 All the above have been checked and indicator light is still on Contact your authorized service representative Prob...

Страница 33: ...tative 171 Possible Backboard service condition Contact an authorized service representative 172 Flow Sensor service condition or flow sensor is unplugged Contact an authorized service representative...

Страница 34: ...ressing C The change will be stored in permanent memory NOTE The Boost mode will normally be activated if the Boost button D is depressed for 10 seconds However if button D is held down an additional...

Страница 35: ...wer 1 9 M1034 Strain Relief Data 1 10 AZ008 Mounting Hardware Kit 1 9 2 Electrolytic Cell Replacement Parts Dwg Kit Description Qty 11 R0403300 R0403400 R0403500 R0403600 Cell w 8 DC Cable PURE700 Cel...

Страница 36: ...flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air o...

Отзывы: