Page 20
Table 3. Pool or Spa Only Controls
Table 4. Dual Equipment Controls
DIP Switch #
OFF
ON
1
Aux. 1 = Any equipment
Aux. 1 = Pool cleaner
2
Aux. 2 = Any equipment
Aux. 2 = Low speed for a two speed
fi
lter pump.
Filter pump circuit becomes high speed.
3
Aux. 3 = Any equipment
Aux. 3 = Spa spillover effect. Combo controls
only.
4
Heater cool down operates.
Heater cool down disabled.
5
Normal operation
Factory adjustment. When this switch is on, tem-
perature delays are eliminated and solar tempera-
ture is displayed. Do not leave this switch in the
ON position.
6
Spare
No change.
7
Spare
No change.
8
After thermostat setting has been reached, the
heater will remain off for three (3) minutes.
After thermostat setting has been reached, the
heater will remain off for
fi
ve (5) minutes.
DIP Switch #
OFF
ON
1
Aux. 1 = Any equipment
Aux. 1 = Pool cleaner
2
Aux. 2 = Any equipment
Aux. 2 = Low speed for a two speed
fi
lter pump.
Filter pump circuit becomes high speed.
3
Spare
No change.
4
Heater cool down operates.
Heater cool down disabled.
5
Normal operation
Factory adjustment. When this switch is on, tem-
perature delays are eliminated and solar tempera-
ture is displayed. Do not leave this switch in the
ON position.
6
Separate pool and spa heaters
Sharing one heater
7
No solar system installed. Air temperature
displayed.
Changes air sensor to solar sensor. Air tempera-
ture no longer displayed. AquaLink RS Adjust-
able Freeze Kit must be added fro freeze protec-
tion.
8
After thermostat setting has been reached, the
heater will remain off for three (3) minutes.
After thermostat setting has been reached, the
heater will remain off for
fi
ve (5) minutes.
Содержание AquaLink RS6
Страница 2: ...Page 2...
Страница 30: ...Page 30 Figure 23 JVA Internal Wiring...
Страница 45: ...Page 45 Notes...
Страница 46: ...Page 46 Notes...
Страница 47: ...Page 47 Notes...