Page 8
Section 3. Controller
3.1 Diagnostics
The AquaLink system has an internal self-checking process, which can display its current status on the indoor control
panel. Use the following steps to get to this "diagnostics" information:
1. All Button: Use the buttons along the lower left side of the controller.
a. Press
MENU
,
BACK,
and
BACK
again until
SYSTEM SETUP
displays on the screen.
b. Press
ENTER
(
*
),
BACK,
and
BACK
again until
DIAGNOSTICS
displays on the screen.
c. Press
ENTER
, and read the information that is presented in order.
NOTE To step through the information faster, press an arrow key (for example, Up). If you make a mistake, select CANCEL
before selecting ENTER again. When done, the controller will return automatically to its normal operating cycle.
2. OneTouch: From the main OneTouch screen, use the
Up
or
Down
arrow button.
a. Highlight
MENU
(press
Select
).
b. Highlight
HELP
(press
Select
), highlight
DIAGNOSTICS
(press
Select
).
c. Press
BACK
when done.
Information displayed includes identification of the exact model number (shown as a four (4) digit firmware number)
and firmware revision letter, and the status of the battery, temperature sensors, and other devices that are currently
working on-line (communicating with the power center). If an LX or LXi heater is on-line, information about its error
condition (if any) will also be shown here.
Содержание AquaLink RS6
Страница 2: ...Page 2...
Страница 30: ...Page 30 Figure 23 JVA Internal Wiring...
Страница 45: ...Page 45 Notes...
Страница 46: ...Page 46 Notes...
Страница 47: ...Page 47 Notes...