JXi
™
Gas Conversion / Replacement Instructions
Section 2: ORIFICE REPLACEMENT
Instructions
These instructions are for replacing parts with identical BTU and fuel
type:
• Gas Orifice
• Air Intake Orifice
You will need the following tools for REPLACEMENT:
• Digital Differential Pressure Manometer
• Manometer Accessories (hoses, tee, fittings)
• Blunt Tool (Key or Phillips Head Screwdriver)
• Pipe Wrench
• Second Pipe Wrench for Removing Gas Union
IMPORTANT: READ BEFORE YOU START
The fuel orifice kit contains critical replacement parts required to
ensure safe reliable operation of the JXi
™
model heater for either fuel
orifice replacement or fuel type conversion. Please note that not all
parts included in the kit will be used for orifice replacement. Some of
the items are used only for the conversion procedure. It is critical that
the parts used for orifice replacement are for the fuel type specified
(either natural gas or propane) and are installed correctly according to
the instructions in this manual.
NOTE:
The design of the JXi heater allows the same gas valve to be
used for both natural gas and propane models.
1. Gas Orifice
The orifice is specific for each BTU and for fuel type. Ensure you have
the correct gas orifice for the BTU and fuel type required by checking
the part number factory-stamped on the gas orifice against Gas Orifice
Markings column, Table 2. In addition, it is critical that the O-ring used
is the one provided by Zodiac
®
in this kit and is BUNA-N type (no
substitutions).