![Jandy Pro Series JXi 200 Скачать руководство пользователя страница 13](http://html2.mh-extra.com/html/jandy-pro-series/jxi-200/jxi-200_installation-instructions-manual_3307703013.webp)
Page 13
JXi
™
Gas Conversion / Replacement Instructions
10. Pressing fi rmly, seat the new gas orifi ce and O-ring fi rmly in the
middle of the union. Use only your fi ngers so as not to damage
the O-ring or the orifi ce. Ensure it is fully inserted and fl at against
the orifi ce seat with the etched surface facing outward for easier
identifi cation of the orifi ce type and size (see Figure 10).
ETCHED SURFACE
O RING
Figure 10. Etched Surface of Gas Orifice
WARNING
To avoid the risk of a gas leak, which can lead to fi re or explosion
resulting in property damage and serious injury, including loss of
life, do not replace the O-ring with anything but a genuine Zodiac
®
custom part included in this kit. No substitution should be made
for the O-ring. Always replace the gas orifi ce and O-ring as one
assembly and use ONLY Zodiac original equipment parts.
11. Reposition and reconnect the gas train to the blower by tightening
the union.
12. There is a sticker on the gas valve indicating the original gas.
Remove this fuel type sticker from the gas valve and discard.