Gas Conversion / Replacement Instructions
STEP 5: Perform Gas Leak Test & Check Heater Operation
1. Reopen the gas supply valve.
2. Test the complete gas supply system and all connections for leaks
using a soap solution (Figure 15).
Do not use an open fl ame to test for leaks.
Figure 15. Spray Soap Solution for Leak Test
CAUTION
Some leak test solutions (including soap and water) may cause corrosion or
stress cracking. Rinse the piping with water after testing.
3. Turn on the heater in Pool or Spa mode via the user interface.
4. Verify current water temperature reading on the user interface, then
confi gure the set point so it is higher than the current temperature.
This will prompt the ignition sequence.
5. Verify the blower starts (this signifi es the ignition sequence
has begun).
6. Verify that the igniter powers up after a 15-second pre-purge.
7. Verify that the heater begins normal operation once fl ame is sensed at
the burner.
8. Turn off the heater via the user interface.