Understanding
Rain
Sensor
Parameters
The
rain
sensor
closes
the
curtains
when
rain
is
sensed
on
the
sensor
element.
You
control
how
much
rain
shuts
the
curtain
by
the
location
the
sensor
is
mounted
and
by
adjusting
the
sensitivity
knob
inside
the
rain
sensor.
Anytime
rain
is
sensed
the
curtain
will
close
for
a
maximum
of
approximately
3
minutes
[parameter
C3].
As
soon
as
the
rain
is
no
longer
sensed,
the
curtain
will
try
to
reopen.
Troubleshooting
&
Amp
Overload
If
your
screen
is
flashing
E
‐
1
thru
E
‐
4
one
of
your
curtains
is
tripped
the
amp
overload.
The
amp
overload
stops
a
motor
if
the
amps
climb
to
high.
This
curtain
will
not
go
again
from
temperature
until
you
clear
it.
The
remaining
curtains
will
continue
working.
Even
if
a
curtain
is
overloaded
you
can
force
it
by
using
the
toggle
switches.
Take
care
when
doing
this.
You
may
be
able
to
figure
out
the
problem
by
forcing
the
curtain.
Force
it
to
go
open.
While
it’s
running,
watch
the
amp
reading
on
the
screen.
If
it
spikes
near
the
top,
the
top
limit
is
not
set
correctly.
My
curtain
overloads
all
the
time.
However
the
curtain
still
moves.
If
a
curtain
overloads
every
couple
of
days
or
less,
you
may
have
a
problem.
It
could
be
the
limit
switch
on
the
motor
is
not
stopping
the
curtain
until
it’s
wrapped
too
tight
or
a
rope,
strap
or
weeds
are
wrapped
in
the
curtain.
My
curtain
overloads
quickly.
Curtain
does
not
move.
You
curtain
motor
maybe
bad.
Also
check
for
damaged
cords
around
the
motor.
Tech
note:
The
controller
does
not
consider
the
motor
overloaded
the
first
time
the
amps
spike
above
the
curtain’s
setpoint.
It
will
try
multiple
times.
It
tries
multiple
times
until
it
decides
the
motor
is
overloaded
for
real.
Default
is
set
to
try
twice.
Example:
If
curtain
tries
to
open,
and
draws
too
may
amps
then
the
curtain
tries
to
open
a
second
time
and
again
draws
too
many
amps
the
curtain
will
be
overloaded
for
Open.
After
a
while
the
curtain
may
try
to
close,
if
the
motor
can
jog
close,
it
will
clear
the
overload.
Now
the
curtain
can
go
open
again.