Curtain
Parameters
Understanding
Curtain
Temperature
Parameters
The
temperature
setpoint
for
each
curtain
controls
when
the
curtain
opens.
If
the
temperature
is
warmer
than
the
setpoint
the
curtain
will
slowly
open.
The
temperature
must
drop
several
degrees
below
the
setpoint
before
the
curtain
will
slowly
close.
The
temperature
deadspan
controls
how
much
the
temperature
must
drop
before
the
curtains
begin
to
close.
Understanding
Curtain
Cycle
Time
The
curtains
use
a
cycle
to
control
how
fast
they
respond
to
temperature
changes.
The
cycle
consists
of
On
seconds
and
wait
minutes.
The
curtain
switches
on
for
P6
seconds
and
then
waits
for
P7
minutes
then
repeats
the
cycle.
Adjust
the
cycle
time
so
the
curtain
takes
approximately
one
hour
to
fully
open
or
close.
Parameter
ID
Description
Default
Min
Max
P1
Curtain
#1
temperature
setpoint
60°
1°
99°
P2
Curtain
#2
temperature
setpoint
60°
1°
99°
P3
Curtain
#3
temperature
setpoint
60°
1°
99°
P4
Curtain
#4
temperature
setpoint
60°
1°
99°
P5
Seconds
the
curtain
is
switched
on
10
5
50
P6
Minutes
the
curtain
waits
until
it
is
switched
on
again
5
2
25
P7
Temperature
difference
between
opening
and
shutting
the
curtain.
If
the
deadspan
is
5.0°
and
the
curtains
setpoint
is
38°,
the
curtain
will
jog
close
when
the
temperature
is
33°
or
less.
5.0
˚
1.0
˚
20.0
˚
P8
Curtain
#1
maximum
amps
.5
125
P9
Curtain
#2
maximum
amps
.5
125
P10
Curtain
#3
maximum
amps
.5
125
P11
Curtain
#4
maximum
amps
.5
125
Table
1
Содержание JDN4-5
Страница 2: ......
Страница 17: ...IS255 21A J D Manufacturing Eau Claire WI 54701 1 800 998 2398 www jdmfg com P a g e 15 ...
Страница 18: ...IS255 21A J D Manufacturing Eau Claire WI 54701 1 800 998 2398 www jdmfg com P a g e 16 ...
Страница 19: ...IS255 21A J D Manufacturing Eau Claire WI 54701 1 800 998 2398 www jdmfg com P a g e 17 SECTION 2 USER GUIDE ...