14
Hatchery Disinfectant Manual
33-1/4'' (845 mm)
Duct
Spray nozzle
Left
Right
38-1/4'' (972 mm)
Front edge
of duct
Rear wall
Spray nozzle
5/8'' (16 mm)
Lateral view
1/2'' (13 mm)
Centre of
spray nozzle
Duct
Front view
T
HE
PX H
ATCHER
The PX Hatcher requires two (2) nozzles, one on ei-
ther side of the intake duct.
The nozzle on the right of the duct must be located
33.25" (845 mm) down from the roof. The centre of
the nozzle must be 0.50" (13 mm) away from the duct
and 0.625" (16 mm) back (towards the rear of the cabi-
net) from the corner of the duct.
Figure 9: Atomizer Placement in the PX Hatcher
The nozzle on the left of the duct must be located 38.25"
(972 mm) down from the roof. The centre of the noz-
zle must be 0.50" (13 mm) away from the duct and
0.625" (16 mm) back (towards the rear of the cabinet)
from the corner of the duct).