background image

 

 

1.2.5  

Device Insertion

 

For chips in DIP package 

Follow the reference diagram next to the socket. Chips are always inserted at the bottom 
line of the ZIF socket with the pin 1 facing toward upper left corner.  For some low-end 
models, some devices may need to be inserted in a non-standard way.  Instruction for 
insertion of such devices will appear on the screen when the selection of the device is 
made. 
 

For chips in None-DIP packages 

Socket adapters are available for PLCC, QFP, TSOP, PSOP, SSOP, SOIC, SDIP, BGA 
etc. packages. All adapters with 48 pins or less are constructed with top and bottom pins 
connected 1 to 1. 

1) Adapters with 48 pins or less on SuperproIII 

Socket adapters are inserted in the same way as DIP packaged devices, which is at the 
bottom of the 48 pin DIP ZIF socket. Chip insertion instruction onto the adapter is 
displayed when the device is selected on the screen. Be sure to insert chips in correct 
orientation. 

2) Chips with more than 48 pins on SuperproIII 

Optional 100 pin expansion adapter, PEP100, is necessary to program larger devices. 
Please remove the standard DIP48 ZIF socket adapter and install the PEP100 adapter in 
place and then mount the socket adapter on top. 
 

 

1.3  Programming Operation      

1.3.1 Quick Guide to Programming

 

Select the device:

 From the main screen, click 

on Select, 

and the 

Select

 window will 

popup. First select the Category of device (E/EPROM, BPROM, SRAM, PLD or MCU) 
followed by Manufacturer and Device name from the screen.  Click OK button or double- 
click the device to confirm selection. Chips may also be selected by typing in the device 
part number in the 

Search 

box. 

 
 To load the data to be programmed with, you may load it from disk or copy master data 
by reading in the master chip.   
 

Loading a file:

 

You may load a file into the buffer by clicking 

File 

menu in the main 

screen and Load File screen will pop up. In the Look In dialog box, select the folder and  
file name you wish to load.   File Type screen will pop up with various data types to 
select from.  At this point, the selected data will be loaded automatically into the buffer. 
Please go to the Buffer and check if the data is loaded properly. 

Note

, Most HEX or S record files contain non-zero file start address. In this case, the start 

address should be entered in the F

ile address

 box.  

                

 

Reading data from master chip: 

Insert the master chip in the socket and make the 

 

Содержание Superpro Series

Страница 1: ...The content and copyrights of the attached material are the property of its owner Distributed by www Jameco com 1 800 831 4242...

Страница 2: ...SUPERPRO series Universal Programmers For Windows 95 98 NT 2000 User s Guide XELTEK...

Страница 3: ...ducts are intended for use by the original purchaser under the terms of the License Agreement This User s Guide is copyrighted All rights are reserved This document may not in whole or part be copied...

Страница 4: ...oftware Installation 1 2 2 Hardware Installation 1 2 3 Running the Program 1 2 4 Communication Error message 1 2 5 Device Insertion 1 3 Programming Operation 1 3 2 Quick Guide to Programming 1 3 3 Err...

Страница 5: ...it Pattern 2 4 3 Delete Pattern 2 4 4 TTL CMOS test 2 4 5 Auto find device 2 4 6 Vector test 2 5 Option Alt O 2 5 1 Setting 2 5 2 Auto Increment 2 5 3 Load configure file 2 5 4 Save configure file 3 A...

Страница 6: ...EPROMs PLDs and Microcontrollers from 60 manufacturers 3 IC test capability for TTL and CMOS Logic ICs model dependent 4 Support for Binary Intel linear segmented HEX Motorola S Tektronix linear segme...

Страница 7: ...etup disc or CD ROM into a drive and run SETUP EXE At the beginning of setup default folder will be created or you may create select the folder of your choice Setup program creates three sub folders B...

Страница 8: ...thout any error message At this point you may select a device and proceed with programming operation Figure1 Main Screen 1 2 4 Communication Error Message Communication error may occur if the PC faile...

Страница 9: ...ard DIP48 ZIF socket adapter and install the PEP100 adapter in place and then mount the socket adapter on top 1 3 Programming Operation 1 3 1 Quick Guide to Programming Select the device From the main...

Страница 10: ...face 2 1 1 Load Ctrl O Files are loaded into one of two buffer types HEX ASCII buffer for EPROMs and Microcontrollers MCU and Logic buffer for PLD PALs which requires JED type file For EPROMs and MCUs...

Страница 11: ...urns you to the control of the operating system 2 2 Buffer Alt B The menu manages data in the buffer 2 2 1 Edit The selection brings up Fuse Buffer Edit window if the device type is a PLD or Data Buff...

Страница 12: ...Address Fill Data input lines OK and Cancel buttons Input desired data to be filled into the Fill Data input line and specify the range by indicating the beginning and ending addresses For the Fuse B...

Страница 13: ...e next search for the search string in Search 2 2 2 Encryption Table The Load Encryption Table with its two sub menus manages an encryption array The two sub menus will appear only if the chip selecte...

Страница 14: ...f the Device and to specify the Word Format Enter on Select to make device selection When you are ready to operate on a device e g program or read click on Run which displays Function dialog box for p...

Страница 15: ...Address display window while the chip is being programmed or verified Read The function reads the content of the chip into the buffer After reading is complete checksum of the data will be displayed a...

Страница 16: ...ctions may be put together using the Edit Auto menu For GAL devices it executes the Erase function at the beginning and sets the security bits at the end Security The function applies to PLDs and MCUs...

Страница 17: ...End are used in multiple file loading and offset programming Multiple loading allows the buffer to be filled with different files at different location Offset programming allow the chip start address...

Страница 18: ...elected will be displayed instantly in the Device column Type radio button allows you to select one of the different device types such as E EPROM PLD MCU etc Select the device type first before select...

Страница 19: ...ion of Odd Word will program only the odd data bytes For example if the data is buffer address 00 01 02 03 04 05 06 buffer data 01 23 45 67 89 AB CD Result after programming will be device address 00...

Страница 20: ...fied in a test pattern allowing quite complex devices to be tested 2 4 1 New Pattern To test a new device that is not included in TTL LIB a new test pattern may be created To access this function clic...

Страница 21: ...You can enter the device name into the input line or select from the list viewer Upon acceptation of the device name the software opens the edit window with the name of the device at the top You may...

Страница 22: ...evice can be listed If the device cannot be found it will display an error message No chip found Only the devices which are registered in the programmer may be found 2 4 6 Vector Test To perform vecto...

Страница 23: ...llows serial number or signature to be embedded into EPROM or MCU devices automatically The selection brings up the Auto Increment set dialogue box You can set Auto start and Auto end addresses in the...

Страница 24: ...is started the file is loaded automatically to restore the previous operational status which includes device related information parallel port and other setup information The file may be edited and sa...

Страница 25: ...echnical assistance have your invoice number ready or quote it in written correspondence Be familiar with the hardware configuration that you are using We may need to know the brand model of your comp...

Страница 26: ...terference All efforts have been made to verify the proper operation of the software and the accuracy of the User s Guide XELTEK does not warrant that the operation of the program will be uninterrupte...

Страница 27: ...ation error Communication searches no programmer connected Software only works in demo mode Make sure programmer powering on search programmer with communication See Setting sub menu again 3 2 3 Algor...

Отзывы: