This opens the
Vector Buffer Edit
window. If a test vector table is included in the
JEDEC file, the software will load the test vector table to the buffer automatically when
the JEDEC file is loaded. Refer to the following when editing the test vector.
Z: High impedance state
X: Don't care state
N: Vcc and ground (output pins are not tested)
H: Output logic High (Voh)
L: Output logic low (Vol)
C: Clock pin
1: Input logic High (Vih)
0: Input logic Low (Vil)
2.3 Device:
<Alt-D>
This menu is used to select programming Functions, IC manufacturer, Device Category,
Part Number of the Device and to specify the Word Format. Enter on
Select
to make
device selection. When you are ready to operate on a device (e.g. program or read), click
on
Run,
which displays
Function
dialog box for programming operation.
2.3.1 Run
The selection is used to perform actual operation on a device, e.g. Program, Read, Blank
Check, Erase, etc. It brings up the
Function
dialogue box and displays information on the
selected device, which are
Function Select
list viewer,
Message
(and the blue
information display windows on the bottom),
Chip Start
,
Chip End
,
Buff Start
,
Buff
End
input lines,
OK
and
Cancel
buttons.
The Function Select list in the Function dialogue box may differ from chip to chip
and it reflects the functions available for the chip from the manufacturer.