Option
: Check
Insertion Test
if you want the programmer to do an insertion test before
any operation on the device. Check
Beeper
if you want the programmer to beep after any
operation. .
Initialize Programmer
: Clicking on communication will search the programmer through
all possible parallel port. If it finds the programmer, the communication will be
successful. If not,
Error
message will appear.
Data Buffer
Clear:
If checked, buffer will be cleared each time IC is changed or when
loading new data from disk. Normally, this should be checked. For multiple file load, it
should be unchecked.
2.5.2 Auto Increment (
model dependant)
The function allows serial number or signature to be embedded into EPROM or MCU
devices automatically.
The selection brings up the
Auto Increment
set dialogue box. You can set
Auto
start and
Auto
end
addresses in the buffer, you can also set increment value with any number less
than 10. The increment format allows increment as Binary, ASCII HEX and ASCII
Decimal. If you want to change the current increment data, open the data edit window and
enter data.
For example, suppose you want to program 64 ea chips with IDs of from XT00 to X63 at
end of EPROM locations of 87C51. 4 bytes of decimal format is selected.
a) Click
Option >
Auto Increment
b) Set
Start
to FFC and
End
to FFF
c) Set
IncValue
to 1
d) Set
Format
to
ASCII Decimal
e) Check out
Enable Auto Increment
f) Go into Buffer Edit screen at ASCII zone. Change buffer as follows:
FFC : X
FFD: T
FFE: 0
FFF: 0