24
9
SI2
The protection stop function input 2, the factory
default is V+
10
SI1
The protection stop function input 2, the factory
default is V+
11
EI2
Emergency stop function input 2, the factory default
is V+
12
EI1
Emergency stop function input 1, the factory default
is V+.
P9
-
-
USB USB3.0
P10
-
-
Ethernet1Gigabit Ethernet interface
4.3.1 All digital I/O common specifications
This section describes the electrical specifications for 24V digital I/O using an electrical cabinet. Can be
divided into: V + power selection, security I / O configuration.
The electrical cabinet supports 16 digital inputs and 16 digital outputs, as shown in Figure 4-2.
Figure 4-2
The digital I/O can be powered by a 24V power supply provided inside the control cabinet and supports up
to 1.5A output (overload will turn off the output). When the user needs more power output, the V+ power supply
can be powered by an external "24V power supply". 24V is the internal power supply and 0V is the internal
ground. V+ is the positive pole of the digital I/O interface, and V- is the negative pole of the digital I/O interface.
The factory default configuration is internal power, see Figure 4-3 below.
JAKAZu 5