Setting range
Default value
Description
Configure pulse generator settings.
1〜4096
165
Set the division value for the prescaler (12 bit) using PixelClock as the base
clock.
0.0181274〜74.25
0.45
Set the clock used for the pulse generator.
This value is calculated using the [ClockPreScaler] value as a base.
PulseGenerator0,
PulseGenerator1,
PulseGenerator2,
PulseGenerator3
PulseGenerator0
Select the pulse generator.
PulseGeneratorLengthValue
1〜1048575
30000
Set the maximum count-up value as a clock count.
PulseGeneratorLength (ms)
ー
ー
Set the maximum count-up value in milliseconds.
This value is calculated using the [PulseGeneratorLength] value as a base.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorFrequency (Hz)
PulseGeneratorClock (MHz) ÷
1048575 x 1000000 〜
PulseGeneratorClock (MHz) x
1000000
ー
Set the maximum count-up value as a frequency.
This value is calculated using the
[PulseGeneratorLength] value as a base.
PulseGeneratorStartPointValue
0〜1048575
0
Set the start point of the High interval as a clock count. When the counter
reaches this value, the output will be 1.
PulseGeneratorStartPoint (ms)
0〜42949.6
0
Set the start point of the High interval in milliseconds.
When the counter reaches this value, the output will be 1.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorEndPointValue
1 〜 1048575
15000
Set the start point of the Low interval as a clock count. When the counter
reaches this value, the output will be 0.
PulseGeneratorEndPoint (ms)
0〜42949.6
0.15
Set the start point of the Low interval in milliseconds.
When the counter reaches this value, the output will be 0.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorPulseWidth (ms)
ー
0.15
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is calculated. The setting
range varies depending on the [ClockPreScaler] value.
PulseGeneratorRepeatCount
0 〜 255
0
Set the repeat count for the counter. When this is set to [0], a free counter is
enabled with no repeat limit.
PulseGeneratorClearActivation
Off,
LevelHigh,
LevelLow,
RisingEdge,
FallingEdge
Off
Set the clear signal condition for the count clear input of the pulse generator.
PulseGeneratorClearSource
Exposure Active,
LVAL,
Pulse Generator[0 - 3],
UserOutput0, UserOutput1,
UserOutput2, UserOutput3,
Line4 TTL In 1,
Line5 Opt IN 1,
Line10 TTL In 2,
Line13 TTL In 3,
Logic Block 0, Logic Block 1,
Encoder Trigger
Low
Select the count clear input signal source.
PulseGeneratorClearSyncMode
AsyncMode, SyncMode AsyncMode
Select the sync mode for the count clear input signal.
PulseGeneratorSelector
PulseGeneratorClock (MHz)
ClockPreScaler
p) PulseGenerator
Item
SW-8000Q-10GE/SW-8000Q-SFP
—
60
—
Содержание SW-8000Q-10GE
Страница 8: ...Parts Identification SW 8000Q 10GE SW 8000Q SFP SW 8000Q 10GE 10 SW 8000Q SFP SW 8000Q SFP 8 ...
Страница 66: ...Spectral Response Wave length nm Relative Response SW 8000Q 10GE SW 8000Q SFP 66 ...
Страница 67: ...Dimensions F mount SW 8000Q 10GE F Dimensional tolerance 0 3mm Unit mm SW 8000Q 10GE SW 8000Q SFP 67 ...
Страница 68: ...M52 mount SW 8000Q 10GE M52 Dimensional tolerance 0 3mm Unit mm SW 8000Q 10GE SW 8000Q SFP 68 ...
Страница 69: ...F mount SW 8000Q SFP F SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 69 ...
Страница 70: ...M52 mount SW 8000Q SFP M52 SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 70 ...