Setting range
Default value
Description
Configure analog control settings.
Off, On
Off
In IndividualGainMode, R, G, B, NIR can be configured individually for the
entire gain adjustment range of the sensor.
IndividualGainMode : On
DigitalGreen,
DigitalRed,
DigitalBlue
IndidualGainMode : Off
DigitalAll,
DigitalRed,
DigitalBlue
ー
Select the gain to configure.
Gain
ー
x1.0
Set the gain value for the gain setting selected in [GainSelector].
[Setting Range]
IndividualGainMode Off : Digital All x 1 〜 x 32 ( 0dB 〜30dB)
Digital Red x 0.67 〜 x 4 (-4dB 〜 12dB)
Digital Blue x 0.67 〜 x 4 (-4dB 〜 12dB)
Digital NIR x 0.67 〜 x 4 (-4dB 〜 12dB)
IndividualGainMode On︓ Digital Green x 1 〜 x 64 (0dB 〜 36dB)
Digital Red x 1 〜 x 64 (0dB 〜 36dB)
Digital Blue x 1 〜 x 64 (0dB 〜 36dB)
Digital NIR x 1 〜 x 64 (0dB 〜 36dB)
DigitalAll,
DigitalRed,
DigitalBlue,
DigitalNIR
DigitalAll
Select the black level to configure.
BlackLevel
DigitalAll -133〜255
DigitalRed -64〜 64
DigitalBlue -64〜 64
DigitalNIR -64〜 64
DigitalAll 0
DigitalRed 0
DigitalBlue 0
DigitalNIR 0
Set the black level value.
Off,
Once,
Preset5000K,
Preset6500K,
Preset7500K
Off
Enable/disable auto white balance.
16〜8192 step 16
8192
Set the area for adjusting white balance.
0 〜 8176 step 16
0
Set the area for adjusting white balance.
ー
Idle
Display the result for adjusting white balance.
0:Idle
1:Succeeded
2:Error1 - G image was too bright
3:Error2 - G image was too dark
4:Error3 - Timeout
0.45, 0.5, 0.55, 0.6, 0.65,
0.75, 0.8, 0.9, 1.0
0.45
Set the gamma value.
Off, Gamma, LUT
Off
Select the LUT mode.
Setting range
Default value
Description
Configure LUT settings.
Red, Green, Blue, NIR Red
Select the LUT channel to control.
0〜256
0
Set the LUT index table number.
LUTValue
0〜4095
Gamma≒1.0
Set the LUT value.
Item
Balance White Auto Width
Balance White Auto OffsetX
Balance White Auto Result
d) Analog Control
e) LUTControl
LUTSelector
LUTMode
Gamma
GainSelector
Balance White Auto
BlackLevelSelector
IndividualGainMode
Item
LUTIndex
SW-8000Q-10GE/SW-8000Q-SFP
—
5
2
—
Содержание SW-8000Q-10GE
Страница 8: ...Parts Identification SW 8000Q 10GE SW 8000Q SFP SW 8000Q 10GE 10 SW 8000Q SFP SW 8000Q SFP 8 ...
Страница 66: ...Spectral Response Wave length nm Relative Response SW 8000Q 10GE SW 8000Q SFP 66 ...
Страница 67: ...Dimensions F mount SW 8000Q 10GE F Dimensional tolerance 0 3mm Unit mm SW 8000Q 10GE SW 8000Q SFP 67 ...
Страница 68: ...M52 mount SW 8000Q 10GE M52 Dimensional tolerance 0 3mm Unit mm SW 8000Q 10GE SW 8000Q SFP 68 ...
Страница 69: ...F mount SW 8000Q SFP F SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 69 ...
Страница 70: ...M52 mount SW 8000Q SFP M52 SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 70 ...