Counter And Timer Control Function
This camera supports only the counter function.
The counter function counts up change points in the camera’s internal signals using
the camera’s internal counter, and reads that information from the host side. This
function is useful for verifying error conditions via the count value using internal
camera operations.
Six counters are available on the camera; Counter0, Counter1, Counter2, Counter3,
Counter4 and Counter5.
The functions that can be counted are fixed for each counter.
Counter0: Counts the number of Line Trigger instances.
Counter1: Counts the number of Line Start instances.
Counter2: Counts the number of Exposure Start instances.
Counter3: Counts the number of Frame Trigger instances.
Counter4: Counts the number of Frame Start instances.
Counter5: Counts the number of Frame Transfer End instances.
When a problem occurs in a system that includes this camera, comparing the values
from multiple counters allows you to verify the extent of normal operability and can
be useful when investigating the cause of the problem.
■
Counter occurrence diagram
Line Trigger
Counter0
Exposure Start
Counter2
Event occurrence
Count up
Counter0
Request
Read out
value
Counter reset
Count up
Counter2
Request
Read count
value
Counter reset
Count 0 reset
Counter2 reset
MCU
HOST
Note
You can reset a specific counter's count value by executing CounterReset[Counter0,
Counter1, Counter2, Counter3, Counter4, Counter5].
Event occurrence
SW-8000Q-10GE/SW-8000Q-SFP
— 40 —
Содержание SW-8000Q-10GE
Страница 8: ...Parts Identification SW 8000Q 10GE SW 8000Q SFP SW 8000Q 10GE 10 SW 8000Q SFP SW 8000Q SFP 8 ...
Страница 66: ...Spectral Response Wave length nm Relative Response SW 8000Q 10GE SW 8000Q SFP 66 ...
Страница 67: ...Dimensions F mount SW 8000Q 10GE F Dimensional tolerance 0 3mm Unit mm SW 8000Q 10GE SW 8000Q SFP 67 ...
Страница 68: ...M52 mount SW 8000Q 10GE M52 Dimensional tolerance 0 3mm Unit mm SW 8000Q 10GE SW 8000Q SFP 68 ...
Страница 69: ...F mount SW 8000Q SFP F SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 69 ...
Страница 70: ...M52 mount SW 8000Q SFP M52 SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 70 ...