Item
Setting value / selectable range
Trigger Mode
On
Trigger Selector
Line Start
Trigger Source
Any
Trigger Activation
LevelHigh
(high-level duration)
,
LevelLow
(low-level duration)
Exposure Mode
TriggerWidth
(control via trigger width)
Item
Setting value / selectable range
Trigger Mode
On
Trigger Selector
Line Start
Trigger Source
Any
Trigger Activation
Rising Edge
(rising edge of input signal)
,
Falling Edge
(falling edge of input signal)
Exposure Mode
Timed
(control via exposure time)
Exposure Time
Varies depending on settings.
Step 5 Configuring Basic Settings for the Camera
1
Set [Exposure Mode] to [Timed].
2
Specify the exposure time in [Exposure Time].
3
Set [Trigger Mode] to [On] and set [Trigger Selector] to [Line Start].
4
If necessary, change the [Trigger Source], and [Trigger Activation] settings.
When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
■
Control via External Triggers
When Controlling the Exposure Time Using the Pulse Width of the Trigger
Input Signal
Configure the settings as follows.
1
Set [Trigger Mode] to [On] .
2
Set [Exposure Mode] to [Trigger Width] .
3
If necessary, change the [Trigger Source] and [Trigger Activation] settings.
SW-8000Q-10GE/SW-8000Q-SFP
— 19 —
Содержание SW-8000Q-10GE
Страница 8: ...Parts Identification SW 8000Q 10GE SW 8000Q SFP SW 8000Q 10GE 10 SW 8000Q SFP SW 8000Q SFP 8 ...
Страница 66: ...Spectral Response Wave length nm Relative Response SW 8000Q 10GE SW 8000Q SFP 66 ...
Страница 67: ...Dimensions F mount SW 8000Q 10GE F Dimensional tolerance 0 3mm Unit mm SW 8000Q 10GE SW 8000Q SFP 67 ...
Страница 68: ...M52 mount SW 8000Q 10GE M52 Dimensional tolerance 0 3mm Unit mm SW 8000Q 10GE SW 8000Q SFP 68 ...
Страница 69: ...F mount SW 8000Q SFP F SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 69 ...
Страница 70: ...M52 mount SW 8000Q SFP M52 SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 70 ...