SW-4010Q-MCL-M52 User Manual (Tentative)
Setting List
- 84 -
CounterAndTimer
Control Item
Setting
Range
Default
Value
Description
CounterStatus
-
0:
CounterIdle
Display the counter status.
0: CounterIdle
2: CounterActive
4: CounterOverflow - Count value exceedded the maximum value.
EncoderControl
Configure the rotary encoder related settings.
Related Topic:
Encoder Control Item
Setting
Range
Default
Value
Description
EncoderSourceA
-
0: Line5
Opt In1
Select where to input the signal from the rotary encoder.
0: Line5 Opt In1
1: Line4 TTL In1
2: Line10 TTL In2
3: Line13 TTL In3
EncoderSourceB
-
0: Line5
Opt In1
Select where to input the signal from the rotary encoder
0: Line5 Opt In1
1: Line4 TTL In1
2: Line10 TTL In2
3: Line13 TTL In3
EncoderDivider
1 ~
32bit
max
65536
Set the number of triggers to be generated during one pitch of the rotary encoder.
The number of triggers is 65536 / (set value).
EncoderAveragingInterval
-
0: none
Perform the internal processing by averaging the time interval of the specified
number of signals.
0: none
1: 2 pulses
2: 4 pulses
3: 8 pulses
4: 16 pulses
5: 32 pulses
EncoderFilter (cycle)
0 ~ 15
0
Apply a low-pass filter to prevent noise on the signal from the rotary encoder and
stabilize the signal for the specified number of cycles.
Note:
10ns/cycle
EncoderStrobe (ns)
1 ~ 256 1
Set the strobe length of the Trigger signal generated from the rotary encoder by the
number of cycles.