SW-4010Q-MCL-M52 User Manual (Tentative)
Setting List
- 85 -
Encoder Control Item
Setting
Range
Default
Value
Description
NonDecimationEncode
IntervalMax
-
0
Enables external setting of the upper limit of the internal frequency calculation result
so that the period of the output frequency is no longer than the user-specified period.
0: none (no max)
1: 1 sec max
2: 2 sec max
3: 3 sec max
4: 4 sec max
5: 5 sec max
6: 6 sec max
7: 7 sec max
8: 8 sec max
9: 9 sec max
10: 10 sec max
UserSetControl
Configure user settings.
Related Topic:
User Set Control
Item
Setting
Range
Default
Value
Description
UserSetSelector
-
0: Default
Select the user settings.
0: Default - Invalid when executing UserSetSave
1: User1
2: User2
3: User3
UserSetLoad
-
-
Read the user settings. When selecting
Default
for UserSetSelector, the
factory settings are loaded.
UserSetSave
-
-
Save the current setting values as user settings. Invalid when
UserSetSelector is set to Default.