SW-4010Q-MCL-M52 User Manual (Tentative)
Main Functions
- 63 -
Counter and Timer Control Function
Related Setting Items:
Note:
This camera supports only the counter function.
The counter function counts up change points in the camera’s internal signals using the camera’s
internal counter and reads that information from the host side. This function is useful for verifying
error conditions via the count value using internal camera operations.
The following counters are available on this camera. The functions that can be counted are fixed
for each counter.
Counter
Description
Counter0
Count the number of Line Trigger instances.
Counter1
Count the number of Line Start instances.
Counter2
Count the number of Exposure Start instances.
Counter3
Count the number of Line Transfer End instances.
Counter4
Count the number of SWIR Line Trigger instances.
Counter5
Count the number of SWIR Line Start instances.
Counter6
Count the number of SWIR Exposure Start instances.
Counter7
Count the number of SWIR Line Transfer End instances.
When a problem occurs in a system that includes this camera, comparing the values from multiple
counters allows you to verify the extent of normal operability and can be useful when investigating
the cause of the problem.