— 50 —
SP-12000M-CXP4 / SP-12000C-CXP4
Item
Setting range
Default value
Description
DeviceTemperature
—
—
Displays the internal temperature (°C) of
the camera.
DeviceReset
—
—
Reset the device.
b) Image Format Control
Configure image format settings.
SensorWidth
—
4096
Displays the maximum image width.
SensorHeight
—
3072
Displays the maximum image height.
SensorDigitizationTaps
10bit
12bit
10bit
Displays the digital tones output from the
sensor.
WidthMax
4096
4096
Displays the maximum image width.
HeightMax
3072
3072
Displays the maximum image height.
Width
128 to 4096
4096
Set the image width.
Height
16 to 3072
3072
Set the image height.
OffsetX
0 to 3968
0
Set the horizontal position.
OffsetY
0 to 3056
0
Set the vertical position.
BinningHorizontal
1, 2
1
Set the number of pixels in the horizontal
direction for which to perform binning.
BinningVertical
1, 2
1
Set the number of pixels in the vertical
direction for which to perform binning.
PixelFormat
SP-12000M-CXP4:
8 Bit Monochrome,
10 Bit Monochrome,
12 Bit Monochrome
(Video Process Bypass
mode only)
SP-12000C-CXP4:
8 Bit BayerGB,
10 Bit BayerGB,
12 Bit BayerGB
(Video Process Bypass
mode only)
SP-12000M-CXP4:
8 Bit Monochrome
SP-12000C-CXP4:
8 Bit BayerGB
Set the pixel format.
TestPattern
Off,
Grey Horizontal Ramp,
Grey Vertical Ramp,
Grey Horizontal
RampMoving,
HorizontalColorBar
(color only),
VerticalColorBar (color
only),
MovingColorBar (color
only)
Off
Select the test image.
TapGeometry
0: Tap_1X_1Y
0: Tap_1X_1Y
Displays the TapGeometry settings.
c) Acquisition Control
Configure image acquisition settings.
AcquisitionMode
Continuous
Select the image acquisition mode.
AcquisitionStart
—
—
Start image acquisition.
AcquisitionStop
—
—
Stop image acquisition.
AcquisitionFrameCount
1 to 65535
153
In [Multi Frame] mode, set the number of
frames to acquire.
Acquisition Frame Rate*
* Frame period depends on
ROI, pixel format, and
binning mode selected."
0.125 to 189.7*
94.8767
In [Multi Frame] mode, set the number of
frames to acquire.
* The fastest value depends on the
setting of the Link Config.
AcquisitionStatusSelector
AcquisitionStatus
TriggerSelector
Acquisition Start,
Acquisition End,
Frame Start
Frame Start
Select the trigger operation.
TriggerMode
Off, On
Off
Select the trigger mode.
TriggerSoftware
—
—
Execute a software trigger
TriggerSource
Low, High, Software, P
ulse Generator 0,
User Output 0,
User Output 1,
Line 4, Line 5,
Line 10, Line11,
NAND0 Out,
NAND1 Out
Line 4
Select the trigger signal source.
TriggerActivation
Rising Edge,
Falling Edge,
Level High, Level Low
Rising Edge
Select the polarity of the trigger signal
(i.e., location of signal at which trigger is
applied).
TriggerOverlap
Off, On
Off
Select the trigger overlap operation.
ExposureMode
Off, Timed,
Trigger Width
Timed
Select the exposure mode.