RM/TM-2040GE Series
40
Configuring the Camera
Figure 24.
LookUp Table
LUTMode:
controls which LUT table to use. There are 2 predefined tables and 1 user configurable table.
Available options:
•
Linear: a linear mapping
•
Gamma45: also known as Gamma 0.45.
•
Knee: you can specify the curve by controlling two points. The camera will calculate the table base on
the Knee values below.
KneeX1:
controls the X value of first Knee point.
KneeY1:
controls the Y value of first Knee point.
KneeX2:
controls the X value of second Knee point. This value must be greater than KneeX1.
KneeY2:
controls the Y value of second Knee point.
KneeSet:
after you have changed the values of the knee points click KneeSet to apply the setting. The camera
will take a few seconds to calculate the LUT table. It is recommended to stop image acquisition during this
time.
LUTInversion:
invert the current LUT table. This creates the negative of image.
5.6
UserSets
These controls are for saving camera settings to the onboard memory and selection of which setting will be
used during bootup.