Configuring the Camera
39
RM/TM-2040GE Series
UserScanAreaStart
: sets the starting line of the User Programmable scan area. First line has a value of 0 and
corresponds to the top of the image sensor. For color cameras (TMC/RMC-2040GE) this value changes the Bayer
pattern of the captured image. Sets PixelFormat to BayerBG for odd value, and BayerGR for even value.
UserScanAreaLines
: sets the number of lines for the height of the User Programmable scan area.
TestImageSelector:
shows a software generated test pattern. Use this feature for debugging purposes.
Available options are:
•
Off: turn off test pattern generator and resume normal operation.
•
DeviceSpecific: shows diagonal lines on black background. Generated by the camera’s CPU.
•
IPEngineTestPattern: shows horizontal striped gradients running right to left.
5.4
Image Preprocessing
As temperature changes the image sensor can produce defective pixels in images, this feature will attempt to
compensate this phenomenon and produce a cleaner image. Run the White Blemish Calibration before using
Blemish Compensation.
•
BlemishCompensation
: enables or disables Blemish Compensation.
•
WhiteBlemishCalibration
: this is done to calibrate the camera so Blemish Compensation can be run. This
is only necessary after a camera has been powered off and restarted. Cover the lens with the lens cap
before calibrating.
5.5
LUT (Look Up Table)
The camera’s Lookup Table is used for dynamic range control when the camera is in 8, or 10-bit output mode.