LQ-401CL
31
Important note:
In this mode, the shutter cannot be used.
Only gain based one-push white balance functions (WB) are available with this mode.
The jitter generated in the trigger input causes a variation of exposure time.
Minimum trigger interval
Scan mode
Trigger input via
Minimum interval (
µ
s)
Full/Binning
Camera link
54.8
12-pin
59.3
Sub-sampling/windowing
Camera link
30.4
12-pin
34.9
Minimum trigger pulse width
Trigger input via
Minimum trigger pulse width
Camera link
500 ns
12-pin
5 µs
Fig. 35 No-Shutter mode with external trigger
TG
179clk
653clk
EEN
790clk
LVAL
16clk
4096clk
16clk
DVAL
Data
AP0