Note: 1) If left side pixel is set at -2 or +2, only Area and 2nd can be configured.
3rd cannot be set.
2) If left side pixel is set at -1 or +1, only Area can be configured.
Caution on calibration:
The object must be charts or materials which have clear and sharp discrimination of white and black
edges. The volume of color difference in peripheral area is measured by using the image analysis
software. Check how many pixels of R and B channels are shifted against G channel. In this function,
maximum three pixels are compensated.
For instance, if R channel is shifted 1 pixel to the left in the left end of the image, this means “-1”
and set the command CABLR to 1.
The compensation for the right side is automatically effected.
6.2.12 Aperture filter
LQ-400CL has a circuit for image enhancement in order to improve visible MTF. The compensation
coefficient is a fixed value and cannot be changed. The factory default for this function is OFF. This
function does not depend on the operating mode.
6.2.13 Binning
In this mode, the camera combines the charge collected in two adjacent pixels. This halves the
effective resolution to 2048 pixels, but doubles the sensitivity. The line rate is not affected by
binning. This function does not depend on the operating mode.
Fig.25 Binning reads out adjacent pixels at the same time
6.2.14 Sub-sampling
In this mode, every two effective pixels are read out. Accordingly, the read out rate is doubled. The
FOV (Field Of View) is not changed versus full scan mode but the resolution becomes half.
Fig.26 Sub-sampling reads out every two pixels
6.2.15 Windowing
In this mode, only the effective 2048 pixels in the center portion can be read out and accordingly,
the readout rate is doubled. FOV becomes half as compared to the full pixel read out. 2048 pixels
are a fixed number and cannot be varied by the user.
4092 4093 4094 4095 4096
4091
4090
4089
4088
4087
1
2
3
4
5
6
7
8
9
10
2048
2047
2046
2045
2044
5
4
3
2
1
1
3
5
7
9
4096
4094
4092
4090
4088
2048
2047
2046
2045
2044
5
4
3
2
1
2
4
6
8
10
4087
4089
4091
4093
4095