User Manual (Ver.1.4) - Setting List
GOX-5105MC-CXP | GOX-8105MC-CXP | GOX-12405MC-CXP | GOX-16205MC-CXP | GOX-20405MC-CXP | GOX-24505MC-CXP
- 127 -
Acquisition Control
Item
Setting Range
Default Value
Description
TriggerSource
-
24: Line5 Opt In
Select the trigger signal source.
7: PulseGenerator0
8: PulseGenerator1
9: PulseGenerator2
10: PulseGenerator3
11: UserOutput0
12: UserOutput1
13: UserOutput2
14: UserOutput3
19: Software
24: Line5 Opt In
26: Line7 Cxp In
36: Nand0 Out
37: Nand1 Out
TriggerActivation
1:Rising Edge
2:Falling Edge
3:Level High
4:Level Low
1:Rising Edge
Select the polarity of the trigger signal (i.e., location of signal at which
trigger is applied).
TriggerOverlap
0: Off (fixed)
1: ReadOut
-
Select the trigger overlap operation.
TriggerSelector(AcquisitionStart) = 0:Off (fixed)
TriggerSelector(AcquisitionEnd) = 0:Off (fixed)
TriggerSelector(FrameStart) = 1: ReadOut
TriggerDelay
0 - 500000
0
Set the time of exposure start from trigger input. (unit: μs)
ExposureMode
Related Topic:
0: Off
1: Timed
2: TriggerWidth
1: Timed
Select the exposure mode.