User Manual (Ver.1.4) - Setting List
GOX-5105MC-CXP | GOX-8105MC-CXP | GOX-12405MC-CXP | GOX-16205MC-CXP | GOX-20405MC-CXP | GOX-24505MC-CXP
- 117 -
DeviceControl Item
Setting Range
Default
Value
Description
DeviceTLVersionMinor
0 (Fixed)
-
Indicates the minor version number of the GenICam XML file of the
selected manifest entry
DeviceTLVersionSubMinor
0 (Fixed)
-
Indicates the sub-minor version number of the GenICam XML file of the
selected manifest entry
DeviceMaxThroughput
390625000
~
781250000
-
Takes the following values according to the setting of
CxpLinkConfiguration. (Unit : Bytes / sec)
Max
CXP6-1
781250000 (Default)
CXP3-1
390625000
DeviceLinkThroughputLimit
Mode
0: Off
1: On
0: Off
0: Off:
Stream packets are sent without gaps.
1: On
: Stream packets will be sent with the gap calculated by the CXP
bandwidth value that was specified by DeviceLinkThroughputLimit.
DeviceLinkThroughputLimit
195312500
~
390625000
-
The setting range is DeviceMaxThroughput/2 to DeviceMaxThroughput.
DeviceStreamChannelCount
1 (fixed)
-
Indicates the number of streaming channels supported by the device.
DeviceStreamChannel
PacketSize
256
~
8192
-
Indicates the packet size in bytes. (Read-only)
DeviceReset
-
-
Reset the device. (After the camera receives this command, it returns an
ACK response. Then, execute reset.)
DeviceTemperatureSelector
0: Main board
1: Sensor
2: FPGA
0: Main
board
Select the area of the camera's interior for which to display the
temperature sensor's reading. (fixed 0: Mainboard)
DeviceTemperature
-55
~
125
0
Display the internal temperature (°C) of the device specified by
DeviceTemperatureSelector.
Timestamp
0
~
64bit max 0
Display the timestamp value (ns). Resets to 0 when the signed
maximum 64-bit value is exceeded.
TimestampReset
-
-
Forcibly sets the timestamp's count value to 0.
TimestampLatch
-
-
Sets the timestamp's count value to TimestampLatchValue.
TimestampLatchValue
0
~
64bit max 0
Maximum value Signed 64-bit max value.
UserDefinedValueSelector
0: Value1
1: Value2
2: Value3
3: Value4
4: Value5
0: Value1
Five 32bit data can be set and saved.
UserDefinedValue
-2147483648
~
2147483647
0
Selects one of the 32bit data (Value1 to Value5) set in
UserDefinedValueSelector, and reads and sets the value in
UserDefinedValue.