Setting range
Default value
Description
Configure pulse generator settings.
1 to 4096
165
Set the division value for the prescaler (12 bit)
using PixelClock as the base clock.
0.0181274 to 74.25
0.45
Set the clock used for the pulse generator.
This value is calculated using the
[ClockPreScaler] value as a base.
Pulse Generator 0
Pulse Generator 0
Select the pulse generator.
Pulse Generator Length
1 to 1048575
30000
Set the maximum count-up value as a
clock count.
Pulse Generator Length (ms)
0.002222222 to
2330.17
66.6667
Set the maximum count-up value in
milliseconds.
This value is calculated using the
[PulseGeneratorLength] value as a base.
The setting range varies depending on the
[ClockPreScaler] value.
Pulse GeneratorFrequency (Hz) 0.429154 to 450000
15
Set the maximum count-up value as a
frequency.
This value is calculated using the
[PulseGeneratorLength] value as a base.
Pulse Generator Start Point
0 to 1048574
0
Set the start point of the High interval as a clock
count. When the counter reaches this value, the
output will be 1.
Pulse Generator Start Point
(ms)
0 to 2330.16
0
Set the start point of the High interval in
milliseconds.
When the counter reaches this value, the output will
be 1. The setting range varies depending on the
[ClockPreScaler] value.
Pulse Generator End Point
1 to 1048575
15000
Set the start point of the Low interval as a
clock count.
When the counter reaches this value, the output will
be 0.
Pulse Generator End Point (ms) 0.00222222 to
2330.17
33.3333
Set the start point of the Low interval in
milliseconds.
When the counter reaches this value, the output will
be 0. The setting range varies depending on the
[ClockPreScaler] value.
Pulse Generator Pulse Width
(ms)
-1.308 to
1.308
33.3333
Display the High interval width of the pulse
in milliseconds.
The duration between the Start Point and End Point is
calculated. The setting range varies depending on the
[ClockPreScaler] value.
Pulse Generator Repeat Count 0 to 255
0
Set the repeat count for the counter.
When this is set to [0], a free counter is enabled with
no repeat limit.
Pulse Generator Clear Activation
Off, HighLevel, LowLevel,
RisingEdge, FallingEdge
Off
Set the clear signal condition for the count
clear input of the pulse generator.
Pulse Generator Clear Source
ー
Low
Select the count clear input signal source.
[Setting range]
Low, High, AcquisitionTriggerWait,
FrameTriggerWait, FrameActive, ExposureActive,
JAIFVAL, JAILVAL, UserOutPut0, UserOutPut1,
Action1, Action2, Line5, Nand0, Nand1
Pulse Generator Clear Inverter True, False
False
Select whether to invert the polarity of the
count clear input signal.
Pulse Generator Clear Sync
Mode
Async Mode,
Sync Mode
Async Mode
Select the sync mode for the count clear
input signal.
Item
Pulse Generator Selector
Pulse Generator Clock (MHz)
Clock Pre Scaler
g) PulseGenerator
— 49 —