GO-5100MC-PGE | GO-5101MC-PGE | User Manual (Ver. 2.0)
Settings List
- 87 -
LUT
Control
Item
Setting
Range
Default
Description
Pulse
Generator
Start Point
(ms)
0 ~ 14.1222
0
Set the start point of the High interval in milliseconds. When the counter reaches this
value, the output will be 1. The setting range varies depending on the Clock Pre-scaler
value.
Pulse
Generator
End Point
1 ~ 1048575
15000
Set the start point of the Low interval as a clock count. When the counter reaches this
value, the output will be 0.
Pulse
Generator
End Point
(ms)
0.000013468 ~
14.1222
33.3333
Set the start point of the Low interval in milliseconds. When the counter reaches this
value, the output will be 0. The setting range varies depending on the Clock Pre-scaler
value.
Pulse
Generator
Pulsewidth
(ms)
0 ~ 14.1222
33.3333
Display the High interval width of the pulse in milliseconds. The duration between the
Start Point and End Point is calculated. The setting range varies depending on the Clock
Pre-scaler value.
Pulse
Generator
Repeat
Count
0 ~ 255
0
Set the repeat count for the counter. When this is set to
0
, a free counter is enabled with
no repeat limit.
Pulse
Generator
Clear
Activation
Off
High Level
Low Level
Rising Edge
Falling Edge
Off
Set the clear signal condition for the count clear input of the pulse generator.
Pulse
Generator
Clear Source
Low
High
Acquisition
Trigger Wait
Frame Trigger
Wait
Frame Active
Exposure
Active
FVAL
LVAL
User Output 0
User Output 1
Action 1
Action 2
Line 5 - Optical
In 1
Nand0 Out
Nand1 Out
Low
Select the count clear input signal source.