GO-5100MC-PGE | GO-5101MC-PGE | User Manual (Ver. 2.0)
Main Functions
- 66 -
Frame Rate Calculation Formula
FR = line frequency ÷ (ROIH ROIH … ROIH 40)
There are two types of line frequencies.
l
10 bit = 1/0.0000134141 = 74.5484 kHz
l
12 bit = 1/0.0000263434 = 37.9602 kHz
Vertical invalid line: 40 (fixed)
Note:
Although the maximum frame rate value is determined by the sensor's line frequency, when
multi-ROI is configured, the frame rate may be limited by the available GigE bandwidth.
Sequence Function
Related Setting Items:
The Sequencer function lets you define up to 128 preset combinations of exposure time, gain, ROI,
and other settings which can be stepped through each time a trigger is received. This is particularly
useful for quickly capturing multiple exposures of objects under inspection to adjust for areas or
components with significantly different levels of reflectance. The order of execution and the repetition
of particular presets are based on user-defined parameters configured in [Sequencer Control].
Two operation modes (Trigger Sequencer mode and Command Sequencer mode) are available for
the Sequencer function.