GO-5000M-PGE / GO-5000C-PGE
- 43 -
8.3.5 Trigger Overlap
In the GO-5000-PGE, the trigger overlap function is fixed to Read Out.
Read Out
:
The trigger pulse can be accepted during the sensor readout.
8.4. Normal continuous operation (Timed Exposure Mode/Trigger Mode OFF)
This is used for applications which do not require triggering.
Primary settings to use this mode
Trigger Mode: Off
Minimum interval of the trigger
Read out mode
Minimum trigger interval
Full
45.2 ms
ROI 2/3 (Height=1365)
30 ms
ROI 1/2 (Height=1024)
22.4 ms
ROI 1/4 (Height=512)
11.4 ms
ROI 1/8 (Height=256)
5.8 ms
1/2V Binning (Note )
22.4 ms
Note: GO-5000M-PGE only
8.5. Timed mode
This mode allows a single image frame to be captured with a preset exposure time by using the
external trigger. Additional settings determine if the trigger pulse can be accepted during the
exposure period.
Primary settings to use this mode
Exposure Mode:
Timed
Trigger Mode: ON
Trigger Source: Opt IN (6p connector)
Trigger Option: OFF
Optical Filter Selector: 10μs
Minimum interval of the trigger
Read out mode
Minimum trigger interval
Full
44.843 ms
ROI 2/3 (Height=1365)
29.962 ms
ROI 1/2 (Height=1024)
22.532 ms
ROI 1/4 (Height=512)
11.377 ms
ROI 1/8 (Height=256)
5.8 ms
1/2V Binning (Note 1)
22.532 ms
Note1
:
GO-5000M-PGE only