GO-5000M-PGE / GO-5000C-PGE
- 16 -
6.2 Digital IN/OUT interface
In the GO-5000M-PGE and GO-5000C-PGE, the digital IN/OUT capability in the software control tool
can assign the necessary signals needed for the system.
6.2.1 Line Selector
In the Line Selector, the following input and output signals can be assigned.
Table-5 Line selector
Note1: Select and connect the line source signal against the item selected in the line selector.
6.2.2 Line Source
Line source signal can be selected from the following table to connect it to the line item
which is selected in the line selector.
Table-6 Line Source
6.2.3 Line Mode
Indicates the status of the interface. (Input, Output or Internal)
6.2.4 Line Inverter
Sets the polarity of the selected input or output. (False or True)
6.2.5 Line Status
Indicates the status of the selected signal, input or output (True=High or False=Low)
Line Selector item
Description
Line 1 Opt 1 Out
Opt 1 output from # 3 of DC In/Trigger 6-Pin on the rear
Line 2 Opt 2 Out
Opt 2 output from #4 of DC In/Trigger 6-Pin on the rear
NAND 0 In 1
No. 1 input to NAND 0 gate in GPIO
NAND 0 In 2
No. 2 input to NAND 0 gate in GPIO
NAND 1 In 1
No. 1 input to NAND 1 gate in GPIO
NAND 1 in 2
No. 2 input to NAND 1 gate in GPIO
Line Source item
Description
Low
Connect Low Level signal to line item selected in Line Selector,
Default setting
High
Connect High Level signal to line item selected in Line Selector
Acquisition Trigger Wait Connect Acquisition Trigger Wait signal to line item selected in Line Selector
Frame Trigger Wait
Connect Frame Trigger Wait signal to line item selected in Line Selector
Frame Active
Connect Frame Active signal to line item selected in Line Selector
Exposure Active
Connect Exposure Active signal to line item selected in Line Selector
FVAL
Connect FVAL signal to line item selected in Line Selector
PulseGenerator0 Out
Connect Pulse Generator 0 signal to line item selected in Line Selector
User Out 0
Connect User Out 0 signal to line item selected in Line Selector
User Out 1
Connect User Out 1 signal to line item selected in Line Selector
Line 5 Opt In
Connect Opt In signal to line 6 in Line Selector
NAND 0 Out
Connect NAND 0 signal to line item selected in Line Selector
NAND 1 Out
Connect NAND 1 signal to line item selected in Line Selector