GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0)
Settings List
- 93 -
JAICustomControlALC
Related Topic:
ALC (Automatic Level Control) Function
Configure JAI ALC settings. These settings are also used for AGC (auto gain control).
ALC
Control
Item
Setting Range
Default
Description
ALC Reference 10 ~ 100
50
Set the target level for ALC. (unit: %)
ALC Area
Selector
Low Right, Low Mid-Right, Low Mid-Left, Low
Left, Mid-Low Right, Mid-Low Mid-Right, Mid-
Low Mid-Left, Mid-Low Left, Mid-High Right,
Mid-High Mid-Right, Mid-High Mid-Left, Mid-
High Left, High Right, High Mid-Right, High
Mid-Left, High Left
Low Right
Select the area for which to configure ALC Area Enable.
ALC Area
Enable
Off
On
Off
Enable/disable the photometry area selected in ALC
Area Selector.
ALC Area
Enable All
Off
On
On
On
: Operate ALC with all areas designated as
photometry areas, regardless of the individual enabled/
disabled photometry area states configured in ALC Area
Selector.
Off
: Operate ALC according to the individual
enabled/disabled photometry area states configured in
ALC Area Selector.
ASC Exposure
Min.
100 ~ 7999727
100
Set the minimum value for the Exposure Auto (ASC)
control range.
ASC Exposure
Max.
101 ~ 7999728
24087
Set the maximum value for the Exposure Auto (ASC)
control range.
AGC Min.
100 ~ 1599
100
Set the minimum value for the Gain Auto (ASC) control
range.
AGC Max.
101 ~ 1600
1600
Set the maximum value for the Gain Auto (ASC) control
range.
AGC/ASC
Control Speed
1 (slow) ~ 8 (fast)
4
Set the reaction speed for AGC/ASC. (8 is the fastest.)