CV-A20
CL / CV-A80
CL
To use this mode
Set function:
Trigger mode "Strobe-Preset Snapshot"
TR = 1
Trigger Input Camera Link or 12-pin Hirose
TI = 0 or 1
Trigger polarity Active-LOW or Active-HIGH
TP = 0 or 1
Window scan select “Full” “Window”
WS=0 or 1
If used
Window scan start
WY=0 to 1079 for CV-A20CL
WY=0 to 1078 for CV-A80CL
Window scan height
WH=1 to 1080 for CV-A20CL
WH=2 to 1080 for CV-A80CL
FVAL Period
* 1 : Strobe Delay Time
The duration from the trigger input to the Strobe signal output can be delayed.
* 2: Readout Begin Period
The Strobe signal is asynchronous in relation to the line rate. FVAL is output synchronous
to LVAL when the Strobe signal is changed from HIGH level to LOW level.
LVAL Period
The timing for LVAL period is the same as the timing for Continuous mode and Windowing.
Trigger minimum interval
The following timing chart explains the period required for new trigger input after the data is
output.
*
A
*
B
Full scan
38L
+
(0 to 1H)
9 L
Window scan
38L
+
(0 to 1H)
9 L
LVAL
EXT TRIG
DATA OUT
STROBE OUT
*1
St robe Enable Delay Time
* 2 Set by Readout begin
* A
*B
FVAL
DVAL
Fig.20. FVAL timing for Strobe-Preset Snapshot mode
16